37987
31
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
32. MOTOR DRIVE PULLEY
a. Remove two screws from bottom edge of front
panel. Refer to Figure 20.
b. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
IMPORTANT: There will always be some water
that will remain in outer tub, therefore, before
removing hoses from pump, hoses must be pinched
off or drained to prevent water spillage.
c. Loosen hose clamps and remove hoses from
pump assembly. Refer to Figure 22.
d. Unhook idler spring from idler lever. Refer to
IMPORTANT: Use care when removing idler
spring. If idler spring is overstretched, washer
operation will be affected.
e. Reach in and around right side of motor and run
belt off right side of large drive pulley. Refer to
Figure 21.
f. Disconnect wire harness from motor switch by
pressing down on locking tab on top of
connection block and at the same time pull
connection block away from motor switch.
Refer to Figure 22.
g. Remove four screws holding motor assembly to
washer base. Refer to Figure 22, then lift
complete assembly out of washer.
h. Lay motor assembly on its side.
NOTE: To remove pulley, support motor shaft (to
prevent bending shaft) and drive out pulley roll pin.
Refer to Figure 24.