68
62631
Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
67. INSTALLING THE NO. 459P3 KIT
a. Remove Phillips head screw (if present), then
apply thumb pressure to the right side of access
door. Refer to Figure 42. When door opens,
move door to the left to disengage from door
supports.
b. Disconnect igniter wires at quick disconnect
blocks. Refer to Figure 48.
c. Remove hex head screw holding burner tube
and igniter in place. Refer to Figure 48.
d. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from gas valve.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
e. Turn burner orifice spud out of gas valve and
install No. 60417 Natural Gas Burner Orifice
Spud (metal stamped #40). Torque new burner
orifice spud to 30 inch-pounds (3.4 N-m).
f. Reinstall burner tube, tighten hex head screw
firmly and reconnect igniter leads.
g. Remove the block open plug and install No.
58768 Vent Screw. Refer to Figure 48.
h. Install No. 60516 “Valve Converted to Natural
Gas” Sticker to top side of gas valve so it covers
the gas valve part number. Refer to Figure 48.
i. Sign and date each of the two No. 60521
Natural Gas Stickers. Install one of the No.
60519 Natural Gas Stickers over the top three
lines of the old sticker on rear of cabinet. Refer
to Figure 44. Then place the second sticker over
the top three lines of the old sticker located on
backside of access door. Refer to Figure 42.
To reduce the risk of electrical shock,
disconnect electrical power to the dryer
before servicing the dryer.
WARNING
To reduce the risk of fire and explosion,
reach in through access door opening and
turn the gas line shut-off valve handle to
the closed position.
WARNING
Figure 48
1 - 3
4 5
DRY967S
APPLY NO. 60516
VALVE CONVERTED
STICKER HERE
CLOSED
POSITION
OPEN
POSITION
BURNER
ORIFICE
SPUD
TOP VIEW OF
GAS VALVE
PRESSURE TAP
PIPE PLUG
HEX
HEAD
SCREW
BURNER
TUBE
IGNITER QUICK
DISCONNECT BLOCKS
SHUT-OFF
VALVE
HANDLE
BLOCK
OPEN
PLUG
BLOCK OPEN
PLUG