62
62631
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
65. BURNER FLAME — Gas Models
Refer to Figure 40
a. Remove Phillips head screw and washer
holding access door to the front panel. Refer to
Figure 42.
b. Apply thumb pressure to the right edge of the
door. When the door opens, move the door to
the left to disengage from the door supports.
Refer to Figure 42.
c. Set temperature switch at NORMAL. Place
coins in slide and carefully push slide in as far
as possible on metered models or set timer at
“60” minutes on nonmetered models.
d. Close the loading door, start the dryer in a heat
setting (refer to the Operating Instructions
supplied with the dryer); the dryer will start, the
igniter will glow red and the main burner will
ignite.
e. Allow the dryer to operate for approximately
five minutes, then open the access door and
loosen the air shutter lockscrew.
f. Turn the air shutter to the right or left to obtain
a soft, uniform blue flame. (A lazy, orange-
tipped flame indicates lack of air. A harsh,
roaring, very blue flame indicates too much
air.)
g. After proper flame is obtained, tighten air
shutter lockscrew securely.
h. Reinstall the access door.
After the dryer has operated for approximately
three minutes, exhaust air or exhaust pipe
should be warm.
For personal safety, the access door must
be in place during normal operation.
WARNING
Figure 40
AIR SHUTTER
LOCKSCREW
AIR
SHUTTER
SHUT-OFF
VALVE
HANDLE
1/8" PIPE PLUG
(For checking manifold pressure)
D265SE3A