58
62631
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
(4) Remove hex head ground screw holding
green ground wire to accumulator
mounting bracket. Refer to Figure 10.
(5) Remove one hex head cap screw (right rear
corner) holding meter case to cabinet top.
Refer to Figure 12.
e. Non-metered models:
(1) Remove four screws and lockwasher
holding timer and plate to timer case. Refer
to Figure 12.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
(2) Pull timer and plate out of timer case as far
as wires will permit. Refer to Figure 8.
(3) Remove screw, lockwasher and locknut
holding ground wires to timer. Refer to
Figure 8.
(4) Disconnect wires from timer. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the timer
f. Remove two screws from the bottom edge of
the front panel. Refer to Figure 13.
g. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 13.
h. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
i. Remove two cabinet top hold-down screws.
Refer to Figure 14.
j. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 15.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind the dryer.
k. Carefully withdraw wire harness through hole
in cabinet top and lift the cabinet top assembly
off the hold-down brackets and set to the side.
Refer to Figure 15.
l. Disengage belt from motor and idler pulleys.
Refer to Figure 28.
NOTE: When reinstalling belt, be sure belt is
properly installed on motor and idler pulleys, and is
on the correct side of the idler lever. Refer to
Figure 28. Belt must be positioned around cylinder
between center and rear baffle screws with the
ribbed surface against the cylinder. After installing
belt, rotate cylinder manually to check that belt is
properly aligned.
m. Remove four screws holding bulkhead to front
flange of cabinet. Lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 32.
IMPORTANT: During reinstallation of front
bulkhead, be sure that air duct is properly
positioned with the flange inside of the felt seal on
the exhaust fan cover.
n. Manually rotate cylinder until one of the baffles
is at the 6 o’clock position and carefully remove
cylinder out through front of dryer.
NOTE: On models using unpainted, corrosion
resistant, coated steel cylinder, the cylinder must be
installed with the side marked “FRONT” or the
arrow pointing toward the front of the dryer.
o. Gas Models
(1) Disconnect igniter wires at disconnect
blocks, sensor wires from sensor terminals,
and wires from gas valve coils at the quick
disconnect blocks. Refer to Figure 19.
(2) Remove screw from right side of burner
housing, holding burner tube in place.
Refer to Figure 23.