24. TIMER
a. Card Reader Models with timer mounted
behind control panel:
(1) Refer to Figure 7 for timer removal.
(2) Remove panel lock (if present).
NOTE: Several turns of the key may be required to
remove panel lock.
(3) Remove two control panel attaching screws
and lift assembly off cabinet top.
(4) Remove two screws holding timer to timer
bracket.
(5) Remove ground screw holding ground wire
to timer.
(6) Disconnect wires from timer.
NOTE: Refer to the appropriate wiring diagram
when rewiring timer.
b. Nonmetered models:
(1) Refer to Figure 8 for timer removal.
(2) Loosen setscrew holding timer knob to
timer shaft and remove knob.
(3) Remove four screws and lockwasher
holding timer and plate to timer case.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
(4) Pull timer and plate out of timer case as far
as wires will permit.
(5) Remove screw, lockwasher and locknut
holding ground wires to timer.
(6) Disconnect wires from timer.
NOTE: Refer to the appropriate wiring diagram
when rewiring the timer.
(7) Remove three screws and lockwasher
holding timer to plate.
NOTE: When reinstalling timer to plate,
lockwasher must be between head of screw and