tector from the inoperative motor switch. Refer to
b.
Motor with Switch on Pulley End.
Press the tip of a
small bladed screwdriver into the slot located between top
of motor switch and plastic clip. Lift up on handle of
screwdriver until both clip and thermal overload protector
detach from motor switch. Refer to
.
4. Attach the thermal overload protector removed in Step “3” to
the new motor switch.
5. Install new motor switch onto motor and reconnect motor
switch leads removed in Step “2”. Refer to
6. Test motor switch by following the step-by-step procedures.
Refer to
.
7. Before reinstalling the motor assembly, apply power (120
VAC) directly to motor terminals 4 and 5. Then start and run
the motor at least 6 times, making sure the motor and switch
are operating properly.
NOTE: The dryer manufacturer and parts suppliers