© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
F8138701
24
Quarterly (UniLinc Control)
NOTE: Disconnect power to the washer-extractor
before performing the quarterly maintenance
procedures.
The Quarterly Menu contains all quarterly service
reminders that need to be performed. Press the
keypad to return to Service Menu.
Verify Vibration Switch Gap
1. Insert the 0.010 inch feeler gauge (supplied with
machine) between the adjustment bolt and the
vibration switch.
2. If alarm is active: Slowly loosen adjustment bolt
until the alarm stops.
3. Very slowly tighten the adjustment bolt until the
alarm activates. The adjustment bolt must be
tightened very slowly to prevent over adjustment.
4. Remove the feeler gauge.
5. Verify the Frame Switch setting.
To adjust the vibration switch gap on the 150 models,
move the vibration switch by adjusting the jam nuts on
the vibration switch.
To return to the Cycle Menu press BACK key several
times until Cycle Menu is displayed.
PHM711N
Figure 22
Service Schedule
Quarterly Maintenance Reminders:
1. Inspect and tighten door hinges and fasteners,
if necessary.
2. Tighten anchor bolts, if necessary.