© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11-06-150R8
103
UniLinc PDA Application (Continued)
Enabling/Disabling Cycles
1. From the
Maintenance Options
menu, press
Enable/Disable Cycles
. The
Communications
screen
appears.
2. Aim the PDA at the “Infrared Comm Port” window on the machine’s control. Press
OK
. The
Enable/Disable Cycles
screen appears.
3. To view the cycle information, press the
Cycle Info
tab. The
Cycle Information
list appears. To
save the cycle information into a text file, press
Create File
.
4. To enable/disable a cycle, press the
On/Off
tab. Press the check box next to the cycle number.
When a check appears in a box, the cycle is enabled. To enable/disable all cycles, press and hold
the screen until the pop-up window appears. Press either
Enable All Cycles
or
Disable All
Cycles
.
5. Press
Send
. The
Communications
screen appears.
6. Aim the PDA at the “Infrared Comm Port” window on the machine’s control. Press
OK
.