Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
(6) Lift back end of coin drop and pull straight
back until bottom edge of drop’s front face
plate falls behind the coin drawer housing.
(7) Carefully lift complete coin drop straight
up and out of meter case.
NOTE: When lifting drop out of meter case, tip
drop slightly so front face plate clears service door
opening. Refer to Figure 36.
b. Installation:
(1) Reverse removal procedures for
installation.
Figure 33
H111SE
3
A
Guide
Wires
Coin
Drop
Locknut
Coin
Drawer
Housing
Control
Cabinet
Front
Disconnect
Block
3/
8
Inch
Square Drive
7/16 Inch
Socket
No. 310P4
1/4 Inch
Ratchet
Extension
Tool
1/4 Inch
Ratchet
Summary of Contents for HWFB61QN1102