Installation
19
512681
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 6: Plug in the Dryer
Electric Dryers with 4-Wire Plug (Supplied
with Dryer)
(120/240 Volt, 60 Hertz, 3-Wire and Ground
Installation)
(120/208 Volt, 60 Hertz, 3-Wire and Ground
Installation)
NOTE: The wiring diagram is located inside the
control hood.
Grounding and Wiring Instructions
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This appliance is
equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided with the appliance –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
The electric service must be a separate branch,
polarized, three-wire and ground, 120/240 Volt, or
120/208 Volt, 60 Hertz, AC single phase circuit fused
with
30 Ampere fuses
.
The cord and plug assembly (supplied with dryer)
should be plugged into an approved receptacle that is
mounted on the wall adjacent to the dryer. This
receptacle should be accessible to the user or service
person when the dryer is in position, to permit
disconnecting when necessary.
NOTE: Branch circuit wire size requirements to
laundry room outlet are shown in
Table 4
.
Figure 20
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1,
and such local regulations as might apply. It
is the customer’s responsibility to have the
wiring and fuses installed by a qualified
electrician to make sure adequate electrical
power is available to the dryer.
W511
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
grounded.
W038
WARNING
Wire Length
Wire
Less than 4.5 m (15 ft.)
Listed No. 10 AWG
Copper wire only
Longer than 4.5 m (15 ft.)
Listed No. 8 AWG
Copper wire only
Table 4
DRY2016N
1
Typical Four-Wire Receptacle
2
Power Cord (Four-Wire)
3
Strain Relief Nut
4
Strain Relief
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
0
V.A.C.
1
2
3
4