Installation
33
801504
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Exhaust System
IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new unit.
For best drying results, recommended maximum
length of exhaust system is shown in
Table 2
.
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
12 in. (30.5 cm) above the ground. Larger
clearances may be necessary for installations where
heavy snowfall can occur.
Number of
90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run Installations
Maximum length of 4" (10.2 cm) diameter rigid metal duct
0
65 feet (19.8 m)
55 feet (16.8 m)
1
55 feet (16.8 m)
47 feet (14.3 m)
2
47 feet (14.3 m)
41 feet (12.5 m)
3
36 feet (11.0 m)
30 feet (9.1 m)
4
28 feet (8.5 m)
22 feet (6.7 m)
Maximum length of 4" (10.2 cm) diameter flexible metal duct
0
45 feet (13.7 m)
35 feet (10.7 m)
1
35 feet (10.7 m)
27 feet (8.2 m)
2
30 feet (9.1 m)
21 feet (6.4 m)
3
25 feet (7.6 m)
17 feet (5.2 m)
4
20 feet (6.1 m)
15 feet (4.5 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
Table 2
D673I
4"
10.2 cm
4"
10.2 cm
2-1/2"
(6.35 cm)
D802I
Summary of Contents for 801504R1
Page 2: ......
Page 4: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 801504 Notes ...
Page 8: ...801504 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 38: ......
Page 40: ......
Page 42: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 40 801504 SP Notas ...
Page 46: ...801504 SP 44 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Page 77: ......