Installation
801504
22
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Plug Connection
Three-Wire Plug
Figure 26
1. Remove access cover from rear of dryer.
Figure 27
2. Use a strain relief and insert end of power cord
through power supply hole.
Figure 28
D816I
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(See NOTE above)
4
Metallic or Non-Metallic Sheathed Cable
(
Copper wire only
)
5
Pigtail to Dryer (See NOTE above)
2
30 Ampere Fuses or Circuit Breaker
6
Neutral
3
Neutral
Wire
7
Terminal Block in Dryer
NOTE: The power cord (pigtail) is NOT supplied with the electric
dryer. Type of pigtail and gauge of wire must conform to local
codes and instructions.
The method of wiring the dryer is optional and subject to local
code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
1
2
3
4
5
6
7
POWER SUPPLY
POWER SUPPLY
INTERMEDIATE
FUSE BOX (May
be omitted if
service entrance
box is fused)
WALL RECEPTACLE
PIGTAIL CONNECTION
L1
L2
L1
L2
DIRECT CONNECTION
INTERMEDIATE
SHUT-OFF BOX
(May or may
not be fused)
120 ± 12
V.A.C.
A typical
30-Amp
Three-wire
Receptacle
NEMA Type
10-30R
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use
COPPER WIRE
only.
’
Shorter than 15
k
(4.5 m) use 10 A.W.G.
Longer than 15
k
(4.5 m) use 8 A.W.G.
D695I
D696I
Summary of Contents for 801504R1
Page 2: ......
Page 4: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 801504 Notes ...
Page 8: ...801504 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 38: ......
Page 40: ......
Page 42: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 40 801504 SP Notas ...
Page 46: ...801504 SP 44 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Page 77: ......