40
503806
Heat Check
(Electric Dryers)
Metered Models
Set the proper FABRIC SELECTOR switch at NORMAL (see Page 51 for
illustration of controls). Place coins in the slide and carefully push slide in
as far as possible, (
IN USE
light will come on indicating the dryer is ready
to operate). Allow coin slide to return to its normal position, or pull out if
necessary. Close the loading door, press the PUSH-TO-START button
firmly, the dryer will start. The dryer will stop if the door is opened. To
restart, close the door securely and again press the PUSH-TO-START
button.
After the dryer has operated for three minutes, the exhaust air or exhaust
pipe should be warm.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and turn timer knob to 50
(see Page 53 for illustration of controls). Close the loading door, press the
PUSH-TO-START button (
IN USE
light will come on indicating start of
cycle). After the dryer has operated for three minutes, the exhaust air or
exhaust pipe should be warm.
Burner Flame
(Gas Dryers)
During the gas heat check, observe the burner flame. The flame can be
viewed by removing the lower front panel of the dryer.
Metered Models
Set FABRIC SELECTOR switch at NORMAL. Place coins in the slide and
carefully push slide in as far as possible. (
IN USE
light will come on
indicating the dryer is ready to operate.) Allow the coin slide to return to
its normal position, or pull it out if necessary. Close the loading door, press
the PUSH-TO-START button firmly. The dryer will start, the igniter will
glow red and the main burner will ignite. The dryer will stop if the door
is opened. To restart, close the door securely and again press the PUSH-
TO-START button.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and turn timer knob to 50.
Close the loading door, press the PUSH-TO-START button, (
IN USE
light
will come on indicating start of cycle, igniter will glow red and main burner
will ignite).
IMPORTANT: If all air is not purged out of the gas line, see Page 23,
the gas igniter may go off before the gas is ignited. If this happens,
after approximately two minutes the igniter will again attempt gas
ignition.