14
503806
Electrical Connection
(Three Wire)
The dryer is grounded to neutral conductor at the
terminal block. If the dryer is installed in a mobile home,
or if local codes do not permit grounding through the
neutral, proceed as shown on Page 17.
To reduce the risk of electric shock, disconnect the
electrical service to the dryer before proceeding.
1.
Remove the screw and terminal block access cover from the rear of the
dryer cabinet.
2.
Insert ends of direct wire through power supply hole (containing proper
strain relief) in rear of dryer cabinet, see page 16. Connect the power
cord,or direct wiring, to the appropriate terminal block terminals using
the
three wire-binding
(10-32x
³⁄₈
")
screws from the
accessories pack in the envelope shipped inside the
dryer cylinder.
If the dryer had previously been connected with a
four-wire power cord, remove the four-wire power cord by reversing
procedures under four-wire power cord, Pages 17 through 19.
IMPORTANT: Use only a U.L. listed No. 10 AWG (copper wire only)
three conductor power supply cord kit rated 240 Volts (minimum) 30
Amperes and labeled as suitable for use in a clothes dryer.
3.
Tighten these wire-binding screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire
failure at the terminal block.
a
WARNING