Allflex NX Series Operational Manual
Page
9
of
14
5.0
POWER
Power requirement. Use the 12vdc power cable supplied and connect to a 12vdc power source.
An external 12-volt battery can be used, or a regulated linear power supply.
DO NOT USE A SWITCH
MODE POWER SUPPLY
as some switch mode power supplies can interfere with the performance of the
system. Voltage range is 12vdc to 14vdc.
The power supply must be approved for use in your country and meet all your countries emission requirements
Only use high quality regulated linear power supplies or solar panels. Please contact Allflex with any queries,
you may have. Some switch mode power supplies are NOT suitable and must not be used.
6.0
CONNECTION INTERFACE
The NX-M supports multiple connection methods to external devices. These include; Bluetooth, WiFi, Serial
and USB. Each connection uses a common connection interface.
See the table below for a full list of commands included in the interface. Each command should be entered
followed by a character return.
Commands
About
v
get software version
rhv
get hardware revision
rut
get unit type
rid
get unit name
rkv
get kernel version
help
list all command information
help 'cmd'
get information about a command
fla
list all files
fi 'file'
file information
sa
download all files
s 'file'
download a file
ca
erase all tag files
c
clear current session
c 'file'
erase a file
se
Same as s but with START/END
sae
Same as sa but with START/END
sla
list all settings
st 'id'
get current value of a setting
ss 'id' 'value'
change the value of a setting
pow
get power information
rar
exit and restart NX-M software
rbt
power off and back on
rpd
power off
load_defaults
Loads factory settings