background image

 

- 3 -

ELECTRIC STOVE INSTALLATION 

Plugging in the heater 

NOTE:  

1.  This heater is for use on 120 Volts. 

2.  A 15AMP circuit is required to operate this appliance. If the breaker trips when the appliance is running, you 

may need to move the appliance to another location or unplug other appliances that are on the same circuit 

3.  ADAPTERS ARE NOT ALLOWED CANADA 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

: A 15AMP,120 Volts circuit is required. Dedicated circuit is preferred but not essential in all cases, a 

dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis 
when the heater is operating. Additional appliance on the same circuit may exceed the current rating of the circuit 
break. 

WARNING

1.  Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the 

power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury 
to persons. 

2.  Construction and electrical outlet wiring must comply with local building codes and other applicable 

regulations to reduce the risk of fire, electric shock and injury to persons. 

3.  Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to 

persons, always use a licensed electrician. 

BEFORE USING THIS APPLIANCE: 

1.  Please check the circuit break for this appliance on? 
2.  Light bulbs may become loose during shipping, if the flame effect is dim or does not operate properly at first, 

ensure that the light bulbs are properly secured in the sockets(bulbs should be finger tight, don’t over tighter) 
see “Replacing Light Bulb” section of this manual for instructions. 

3.  The information regarding this appliance can be found on the rating plate located on the back of the unit 

PLUGGING IN THE HEATER: 

1.  Make sure the appliance main “

I

/O” 

is switch OFF(refer to operating instruction section) 

2.  Plug the unit into a no less 15Amp/120V outlet. 

 

 

 

 

 

Summary of Contents for EA0045RC

Page 1: ... procedures and warranty Put it and the original invoice in a safe dry place for future reference Table of Contents PAGE IMPORTANT SATETY INSTRUCTIONS 2 DIMENSIONS 3 TECHNICAL SPECIFICATIONS 3 WIRING DIAGRAM 3 ELECTRIC STOVE INSTALLATION 4 OPERATING INSTRUCTIONS 4 MAINTENANCE 5 TROUBLE SHOOTING 6 WARRANTY 6 ...

Page 2: ... then remove the plug from the outlet 9 This appliance has a polarized plug one blade is wider than the other This plug will fit in a fully in a outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does fit contact a qualified electrician to install the proper outlet Do not change the plug in any way 10 Do not insert or allow foreign objects to enter any ve...

Page 3: ...DIMENSIONS TECHNICAL SPECIFICATIONS Model EA0045RC Rate Voltage AC 120V 60Hz Rate Power Total 1400W Power of Heating Apparatus 650W 1300W Flame Power 80W Motor Power 20W Specification of the Bulb 2 pcs E12 ...

Page 4: ...ripping or snagging to reduce the risk of fire electric shock or injury to persons 2 Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electric shock and injury to persons 3 Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric shock or injury to persons always use a lice...

Page 5: ...he dimmer button C or dimmer button L on the remote control again to lock in desired flame brightness The red light will remain on This brightness will be kept until the dimmer button C or dimmer button L on the remote control is pressed again HEAT SETTING 1 Turning on Master Power Switch A and O I On Off button B or O I button M on the remote control 2 Press 650W button D or 650W button K on the ...

Page 6: ...ny reason it will automatically turn all heater functions of the appliance off The appliance will have to be reset prior to continuing use To reset the overheat protection safety device turn all controls off and unplug the appliance wait 10 minutes plug the appliance back in and turn on MAINTENANCE REPLACING LIGHT BULBS 1 Ensure that all controls are off the appliance is unplugged and bulbs are co...

Page 7: ...he support bracket No warm air is coming from the heater 1 The overheat protection device in the appliance has been triggered 1 Turn all controls off unplug the appliance allow to cool for at least 10 minutes plug back in and restart The appliance turns off and will not turn back on 1 The overheat protection device in the appliance has been triggered 2 House circuit breaker has been tripped 1 Turn...

Page 8: ...een overloaded or used improperly or subject to neglect or attempted repairs other than by an authorized agent Heavy duty daily professional or hire usage are not guaranteed We are not responsible for any costs related to labour injuries or any other loss incurred during the product installation repair or replacement including any indirect or consequential damages If you have any problems with how...