5. Insert bulbs (D) and secure by twisting 

and locking. 

Adjust heads to desired position.

Printed in China

5

  D

5

CARE AND MAINTENANCE

Clean this unit periodically. Clean the surface finish only with a soft cloth and mild cleaning solution. 

  Dry with a soft cloth. Never use rough cloth, abrasives or chemical cleaners containing acids 

  or harsh solvents.

TROUBLESHOOTING

LIMITED WARRANTY

Manufacturer warrants all of its lighting fixtures against defects in materials and workmanship for one (1) 

year from the date of original purchase.  Electronic parts including passive infrared devices, photoelectric 

switching mechanisms, and light bulbs provided by the manufacturer are warranted for 30 days from the 

date of original purchase. “Energy Star” product, with the exception of the bulb, is warranted for two (2) 

years. “Energy Star” bulbs are warranted for 10,000 hours.

This warranty does not cover parts becoming defective due to misuse, accidental damage, improper 

handling and/or installation and specifically excludes liability for indirect, incidental or consequential 

damages. Product found to be defective may or may not be replaced with same or like type product, 

contingent on the nature of the defect, and/or replacement availability and/or compensated for at a 

pro-rated value.

Some states do not allow limitations on how long an implied warranty lasts, and/or the exclusion or 

limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to 

you. This warranty gives you specific rights and you may also have other rights, which vary from 

state to state.

PROBLEM

POSSIBLE CAUSE

CORRECTIVE  ACTION

Fuse blows or circuit 

trips when fixture is 

turned on.

Light will not turn on. 2. Bad main supply 

    wiring.

3. Defective switch.

Wrong wiring or power 

wire is grounding out.

3. Consult a certified professional electrician.

2. Consult a certified professional electrician.

Consult a certified professional electrician.

1. Replace bulb.

1. Bulb is burned out.

Lowes.com/allenandroth

allen + roth

®

 is a registered trademark 

of LF, LLC. All rights reserved.

Summary of Contents for 18302-000

Page 1: ...blems missing parts Before returning to your retailer call our customer service department at 1 866 439 9800 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday Fran ais p 6 Espa ol p 11 ATTACH YOU...

Page 2: ...TY A B C D Mounting bracket preassembled to Canopy F 1 2 1 6 Canopy screws preassembled to Canopy F Fixture assembly Bulbs E 2 Hexagon nuts F 1 Canopy G 2 Stems B C E F D G PART DESCRIPTION QUANT QUAN...

Page 3: ...event electrical shock CAUTION Refer to the relamping label located near the lamp holder for the recommended maximum wattage DO NOT EXCEED RECOMMENDED WATTAGE ELECTRICAL CONNECTIONS Required Supply Ci...

Page 4: ...on Mark the location of the stems G on the ceiling Secure the stems G to the ceiling support stem bushing DD 4 B C 3 Make electrical connection using wire connectors BB Refer to ELECTRICAL CONNECTIONS...

Page 5: ...se accidental damage improper handling and or installation and specifically excludes liability for indirect incidental or consequential damages Product found to be defective may or may not be replaced...

Page 6: ...produit votre d taillant appelez notre service la client le au 1 800 439 9800 du lundi au jeudi entre 8 h et 18 h HNE ou le vendredi entre 8 h et 17 h HNE JOIGNEZ VOTRE RE U ICI Num ro de s rie Date...

Page 7: ...Pi ce Description Quantit A B C D Traverse pr assembl e au couvercle F 1 2 1 6 Vis de couvercle pr assembl es au couvercle F Luminaire Ampoule E 2 crous hexagonal F 1 Couvercle G 2 Tiges C B A D E F...

Page 8: ...ion La bo te doit tre directement retenue par la structure de l immeuble Pour conna tre la puissance maximale watts recommand e reportez vous l tiquette sur le remplacement de l ampoule pr s de la dou...

Page 9: ...e F avec les vis du couvercle B Placez les bras r glables du luminaire C dans la position d sir e Indiquez l emplacement des tiges G sur le plafond Pour une installation sur un plafon d en cloison s c...

Page 10: ...d une manipulation ou d une installation inad quate et elle exclut express ment toute responsabilit pour des dommages indirects accessoires ou cons cutifs Tout produit qui s av re d fectueux sera remp...

Page 11: ...a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 866 439 9800 de lunes a jueves de 8 00 a m a 6 00 p m y los viernes de 8 a m a 5 p m hora est ndar del Este ADJUNTE SU RECIBO AQU N...

Page 12: ...ad A B C D Abrazadera de montaje preensamblada en la cubierta F 1 2 1 6 Tornillos de la cubierta preensamblados en la cubierta F Ensamble de la l mpara Bombillas E 2 Tuercas hexagonales F 1 Cubierta G...

Page 13: ...tal mpara para ver el vataje m ximo recomendado no exceda el vataje recomendado CONEXIONES EL CTRICAS Circuito de suministro requerido 120 V 60Hz Conecte el los conductor es blanco s de la l mpara al...

Page 14: ...os de la cubierta B Coloque los brazos regulables del ensamble de la l mpara C en la posici n deseada Marque la ubicaci n de los v stagos G en el techo Para instalaci n en techo de panel de yeso utili...

Page 15: ...y excluye toda responsabilidad por da os indirectos accidentales o resultantes Un producto defectuoso puede o no puede ser reemplazado por el mismo tipo de producto o uno similar dependiendo de la na...

Reviews: