Frame 3A and 3B Installation
3-13
PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual
Removing the Active
Converter Power Module
Control Cassette
Frame 3A Drives
For Frame 3A regenerative-type drives, the combined Active Converter/
Inverter Power Module is equipped with an Active Converter control
cassette.
shows the location and removal of this cassette to
access its terminal blocks for control wiring. See the PowerFlex 700 Active
Converter Power Module User Manual, publication PFLEX-UM002, for
control wiring details.
Figure 3.13 Removing the Frame 3A Active Converter Control Cassette
Frame 3B Drives
For Frame 3B regenerative-type drives, the separate Active Converter
Power Module is equipped with a control cassette.
Figure 3.14
shows the
location and removal of this cassette to access its terminal blocks for control
wiring. See the PowerFlex 700 Active Converter Power Module User
Manual, publication PFLEX-UM002, for control wiring details.
Internal DPI Cable
Synchronization Cable
(For use with 700 Vector Control only)
Synchronization Cable
(For use with 700S Phase II Control only)
40-Pin
Ribbon Cable
Pin 1
P2
Detail
P1
Communications
Adapter Option