Configuration Mode
Chapter
4
•
Advanced settings for printing diagnostic and alarm messages
determines when to print messages sent to the network or USB port.
4.
Press OK when done.
5.
Press OK to return to Terminal Settings.
Print Messages After
Default Value
Example
Specified number of messages
60 messages
When the queue has 60 messages, the messages are printed
regardless of how long they have been in the queue.
You can change the number of messages.
500 messages or timeout period,
whichever is first
168 hours (7 days)
If the queue has 350 messages after 168 hours, the 350
messages are printed.
You can change the timeout period.
Specified number of messages or timeout
period, whichever is first.
60 messages
168 hours (7 days)
If the queue has 60 messages after 24 hours, then the 60
messages are printed.
You can change the number of messages and the timeout
period.
For example, the number of messages is set to 75 and the
timeout period is set to 48 hours.
·
If the queue has 75 messages after 24 hours, then the 75
messages are printed before the set timeout of 48 hours.
·
If the queue has 15 messages after 48 hours, the 15
messages are printed after the set timeout period.