MSR41 Safety Module User Manual

Or

i

g

i

nal 

i

nstruct

i

ons

Figure 6: MSR41 base module, Micro 400 Light Curtain, automatic start, output monitoring

Figure 7: MSR41 Base module and MSR45E expander module, Micro 400 Light Curtain, 
automatic start, output monitoring

Status out

p

uts

The MSR41 base module has two status outputs (“Info1” and “Info2”). 
A description of these outputs is given below.  

The following table shows the logic of the two status outputs. The state 
of the status outputs will also be displayed through LED, visible on the 
front side of the main module.

Table 1 

LED d

i

s

p

lay ele

m

ents

MSR41 base 

m

odule

Table 2 gives information about the LED on the front side of a MSR41 
base module with the basic configuration:

Table 2: LED description

Res

p

onse t

im

e

General

• The response time of a MSR41 base module depends on the 

connected GuradShield Micro400 Light Curtain length and 
resolution. 

• The response time for the MSR41 base module [t(totLCOSSD)] 

with respect to the Micro400 light curtain is the sum of the base 
module response time t(C) + the response time of the light curtain 
t(LC): 
t(totLCOSSD)= t(C) + t(LC)

• The response time for the MSR45E expander module (relay safety 

output) [t(totLCEXT)] with respect to the Micro400 light 
curtain  is the sum of the base module response time 
t(totLCOSSD) + the response time of the expander module 
t(em):
t(totLCEXT)= t(totLCOSSD) + t(em)
=t(C) + t(LC) + t(em)

The total response time of a system is the sum of each response time: 

Table 3: Calculation for the total response time of the Micro400 safety light curtain

Terminal

(LED)

Output "high"

(+24V)

Output "low"

(0V)

Info1 (LED)

Start ok (green)

No  start possible (red)

Info2 (LED)

System okay (green)

Error (Lock out) (red)

These outputs may not perform any 
safety relevant functions. They serve only 
to communicate the status to a machine 
controller.

LED

Signal / Color / Status

Signal / Color / Status

OSSD2

+24 V / green /

Light curtain not activated 

(free)

0 V / red / Safe400 

Light curtain activated 

(interrupted)

OSSD1

+24 V / green / 

Light curtain not activated 

(free)

0 V / red / Safe400 

Light curtain activated 

(interrupted)

Info2 (LED)

See page  3

See page  3

Info1 (LED)

See page  3

See page  3

IN2

+24 V / green /

start release okay

0 V / red /

no start release signal

IN1

not  used / green

not used / green

0 V

-

-

+24 V

+24 V / green / 

power connected

0 V / off / 

no power connected

Response time MSR41

Max. OSSD response time for Micro400 
light curtain

t(totLCOSSD) = 9.10ms(t(c)) + t(LC) 
from the Micro400 label

Response time first, 
2nd and 3rd expander 
module

Max. relay extension module response 
time for Micro400 light curtain

t(totLCEXT) = 9.10ms(t(c)) + 
6.00ms(t(em)) + t(LC) from the 
Micro400 label

Summary of Contents for MSR41

Page 1: ...MSR41 Safety Module User Manual ...

Page 2: ...SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation sales office describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication It is recommended that you save this us...

Page 3: ...in The base module offers two safety PNP outputs OSSD Additional expansion modules MSR45E can be applied for applications which require more outputs and or dry contacts to switch loads Special features The outstanding characteristics of the MSR41 controller Category 4 PL e according EN ISO 13849 1 Type 4 according EN 61496 1 2 SIL 3 according IEC 61508 SIL CL 3 according EN 62061 Short response ti...

Page 4: ...cation in explosive EX or in radioactive environments Dimensions The dimensions of the housing for MSR41 are illustrated in Figure 2 Figure2 Basemoduledimensionsarethesameforexpansionmodules Terminal connection diagram The following figures shows the connection possibilities for the MSR41 base module Figure3 MSR41Basemodule Micro400LightCurtain automaticstart nooutput monitoring Figure4 MSR41Basem...

Page 5: ...t to the Micro400 light curtain is the sum of the base module response time t totLCOSSD the response time of the expander module t em t totLCEXT t totLCOSSD t em t C t LC t em The total response time of a system is the sum of each response time Table3 CalculationforthetotalresponsetimeoftheMicro400safetylightcurtain Terminal LED Output high 24V Output low 0V Info1 LED Start ok green No start possi...

Page 6: ...utomatic start or manual start Manual start Depressing the start button will cause the two safety OSSD outputs to change from low to high and if connected the MSR45E relay expander modules will close manual start Automatic start If the MSR41 is connected for automatic start then after the activation and the deactivation of the GuardShield Micro 400 the two OSSD outputs will change automatically fr...

Page 7: ... Technical Data 1 In cases where the MSR41 base module is installed without expander modules the function output monitoring must always be realized the only exceptions are if the PNP outputs are connected with another safety relay or a safety PLC 2 Through the use of output monitoring it is possible to switch external power contactors within the safety circuit Such contactors often deal with large...

Page 8: ...puts unloaded maximal 1 7 A depending on attached load Max power consumption at max supply voltage 2 1 W semiconductor outputs unloaded Controller protection external 5 A slow Control current into IN 1 IN 2 2 mA each min in accordance with EN 61131 2 Minimum voltage at IN 1 IN 2 11 VDC at activated controller EN 61131 2 Start pulse duration Min 50 ms Maximum cable length for safety switches 50 m o...

Page 9: ... Safety of machinery Electro sensitive protective equipment Part 1 General requirements and tests IEC 61496 2 2006 Safety of machinery Electro sensitive protective equipment Part 2 Particular requirements for equipment using active opto electronic protective devices AOPD s EN ISO 13849 1 2008 Safety of machinery Safety related parts of control systems Part 1 General principles for design EN 61508 ...

Page 10: ...1 base module 440R P226AGS NNR MSR42 base module 445L 104794 B MSR42 base module customer configuration 440R P4NANS MSR45E expander module 445L 1 MSR45E expander module customer configuration 1 Denotes characters representing options that do not impact the standards or directives cited on this DoC 2 If no series number is given then all series are covered ...

Page 11: ...ud koopia tootja instruktsioonidega keeles mida ta ise valdab Instruktsioonid erinvates keeltes on saadaval siin http rockwellautomation com literature SUOMI Tämä tuote voidaan asentaa vasta kun asentaja on hankkinut valmistajan ohjeet kielellä jota hän ymmärtää Erikieliset ohjeet ovat ladattavissa sivustolta http rockwellautomation com literature ΕΛΛΗΝΙΚΆ Εγκατάσταση του προϊόντος αυτού δεν πρέπε...

Page 12: ...laan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 10000172476 Ver00 CSA 108 499 Copyright 2011 Rockwell Automation Inc All Rights Reserved Printed in USA April 2011 GuardShield is a trademark of Rockwell Automation Inc Guardmaster is a...

Reviews: