Publication 1766-RM001A-EN-P - October 2008
184
Timer and Counter Instructions
CTD Instruction Counter Control and Status Bits, Counter Word 0
(Data File 5 is configured as a timer file for this example.)
Bit
Is Set When:
And Remains Set Until One of the Following
Occurs:
bit 11 - C5:0/UN
UN - underflow
indicator
the accumulated value wraps from
-32,768…+32,767 and continues to count
down
a RES instruction with the same address as the
CTD instruction is enabled
bit 13 - C5:0/DN
DN - done
indicator
accumulated value
≥
preset value
•
accumulated value
<
preset value or,
•
a RES instruction with the same address as the
CTU instruction is enabled
bit 14 - C5:0/CD
CD - count down
enable
rung state is true
•
rung state is false
•
a RES instruction with the same address as the
CTD instruction is enabled