Connect the Kinetix 350 Drive System
Chapter 4
Wire the Input Power (IPD) Connector
Table 26 - Input Power (IPD) Connector
L3
L2
L1
PE
L3
L2
L1
L2/N
L1
N
PE
L2/N
L1
N
L2
L1
PE
L2
L1
Kinetix 350
Drive
Drive Cat. No.
Terminals
Recommended
Wire Size
mm² (AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2097-V31PR0-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
L3
L2
L1
PE
(1)
L2/N
L1
N
PE
(2)
L2
L1
PE
(3)
2.5 (14)
7 (0.28)
0.5 (4.5)
2097-V32PR4-LM
2097-V33PR5-LM
4.0 (12)
7 (0.28)
0.5 (4.5)
2097-V31PR2-LM
2097-V33PR6-LM
6.0 (10)
7 (0.28)
0.56…0.79
(5.0…7.0)
(1) Applies to 2097-V33PR
x
-LM, and 2097-V34PR
x
-LM drive modules.
(2) Applies to 2097-V31PR
x
-LM drive modules.
(3) Applies to 2097-V32PR
x
-LM drive modules.