FLEX 5000 Terminal Base Assembly Specifications – 5094-TB3, 5094-TB3S, 5094-TB3XT, 5094-TB3SXT, 5094-TB3T, 5094-TB3TS, 5094-TB3TXT, 5094-
TB3TSXT, 5094-TB3W, 5094-TB3WS, 5094-TB3WXT, 5094-TB3WSXT

Attribute

5094-TB3, 5094-TB3S, 5094-TB3XT, 
5094-TB3SXT

5094-TB3T, 5094-TB3TS, 5094-TB3TXT, 
5094-TB3TSXT

5094-TB3W, 5094-TB3WS, 5094-TB3WXT, 
5094-TB3WSXT

Sensor Actuator Power (SA), max

10 A @ 18…32V DC

Input/output ratings (IN/OUT), max

2A @ 32V DC

Input ratings (IN), max

100 mA @ 10V DC

Output ratings (OUT), max

2 A @ 125V DC
2 A @ 240V AC, 50/60 Hz

Sensor Source Voltage (SSV) output ratings, max

1.8 A @ 24V DC

Resource

Description

FLEX 5000 I/O Modules Specifications Technical Data, publication 

5094-TD001

Provides FLEX 5000 I/O module specifications.

FLEX 5000 Digital 16-point Sinking Input Modules Installation Instructions,
publication 

5094-IN003

Provides information on how to install FLEX 5000 digital input I/O modules.

FLEX 5000 Digital 16-point Sourcing Output Modules Installation Instructions,
publication 

5094-IN004

.

Provides information on how to install FLEX 5000 digital output I/O modules.

FLEX 5000 Digital 8-point Isolated Relay Output Module Installation Instructions,
publication 

5094-IN005

Provides information on how to install FLEX 5000 digital relay output I/O modules.

FLEX 5000 Analog 8-channel Current/Voltage Input Modules Installation Instructions,
publication 

5094-IN006

Provides information on how to install FLEX 5000 analog input I/O modules.

FLEX 5000 Analog 8-channel Current/Voltage Output Modules Installation Instructions,
publication 

5094-IN007

Provides information on how to install FLEX 5000 analog output I/O modules.

FLEX 5000 Analog 8-channel Current/Voltage/RTD/ Thermocouple Input Modules Installation 
Instructions, publication 

5094-IN008

Provides information on how to install FLEX 5000 analog RTD/Thermocouple input I/O modules.

FLEX 5000 High-speed Counter I/O Modules Installation Instructions, publication 

5094-IN009

Provides information on how to install FLEX 5000 high-speed counter I/O modules.

FLEX 5000 Shield Bar Product Information, publication 

5094-PC002

Provides specifications for the shield bar and jumper accessories.

Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

 

Provides general guidelines for installing a Rockwell Automation industrial system.

Product Certifications website,

http://www.rockwellautomation.com/global/certification/overview.page

.

Provides declarations of conformity, certificates, and other certification details.

Summary of Contents for FLEX 5000

Page 1: ...ovable terminal blocks needed as a terminal base for your specific FLEX 5000 I O modules Terminal base assemblies are a required part of the FLEX 5000 I O system FLEX 5000 I O systems are used with so...

Page 2: ...cati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cablagg...

Page 3: ...s dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp ratur...

Page 4: ...andle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components ins...

Page 5: ...XT 5094 RTB3S 5094 RTB3SXT RTB MB FRONT VIEW Backplane connector DIN rail mount System connector Threaded insert for RTB captive fastener DIN rail actuator RTB locking pegs FRONT VIEW Keyswitches set...

Page 6: ...0 I O modules MB type depends on your system requirements Refer to FLEX 5000 I O Modules Specifications Technical Data publication 5094 TD001 for system requirements Removable terminal block RTB type...

Page 7: ...tion see the publications that are listed in Additional Resources on page 15 Tools The following tools are needed screw driver such as the 1492 N90 terminal block screw driver with hardened 3mm diamet...

Page 8: ...shield bar to the bottom row of terminals on the 5094 RTB3 or the 5094 RTB3T 1 Insert the mounting hooks of the shield bar into the holes under the last row of terminals on the RTB 2 Pivot the shield...

Page 9: ...urely mounted You can use an Allen Bradley 199 DR1 46277 3 EN50022 35 x 7 5 mm 1 38 x 0 30 in DIN rail with a FLEX 5000 I O system RemoveorReplaceOptionalSAPowerJumpersfromTerminalBases 1 Unscrew term...

Page 10: ...e 8 RemoveorReplacetheTerminalBase 1 If there is an I O module installed remove the I O module from the terminal base 2 Turn the DIN rail actuator to the unlocked position 3 Carefully pull the termina...

Page 11: ...dividual I O module installation instructions 5 Connect V DC power to terminal SA 6 Connect V DC common to terminal SA WARNING If you connect or disconnect wiring while the field side power is on an e...

Page 12: ...terminal base WARNING If you connect or disconnect wiring while power is applied an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is rem...

Page 13: ...nalog Output Module Specialty Module Counter Module Modules with total SA loading 10 A Modules with total SA loading 10 A Modules with total SA loading 10 A Modules with total SA loading 80 of SA 5094...

Page 14: ...allation instructions for your specific I O module Insulation stripping length Screw 0 34 2 5 mm2 22 14 AWG 12 mm 1 mm 0 47 in 0 04 in Spring 0 34 1 3 mm2 22 16 AWG 10 mm 1 mm 0 39 in 0 04 in 2 5 mm2...

Page 15: ...cing Output Modules Installation Instructions publication 5094 IN004 Provides information on how to install FLEX 5000 digital output I O modules FLEX 5000 Digital 8 point Isolated Relay Output Module...

Page 16: ...needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e...

Reviews: