background image

 

 

 

Compact I/O Cable for DriveLogix5730 Controller           

5

Publication 20D-IN008A-EN-P - April 2004

System Configurations

The following illustration show examples of four valid system setups.

Bank 1

1

I/O Slot Number

1769 I/O

1769 Powe

Sup

ply

176

9 I/O

Po

wer

Flex

 700

Dri

ve

Dr

iv

eL

ogix

2

176

9 I/

O

Bank 1

Bank 2

1769

-CRL

3

1769

-CRL

3

176

9 I/O

1769

 Pow

er 

Su

pply

1769

 I/O

176

9 En

d Cap

20

D

-D

L2

-CL2

17

69 I

/O

17

69 Po

wer

 Supp

ly

Powe

rF

lex

 7

00S Dr

iv

e

D

riv

eL

og

ix

1

I/O Slot Number

2

3

4

20D

-DL

2-

C

L2

Dr

iv

eL

ogix

Power

Flex

 70

0S Dr

ive

17

69 P

owe

r Sup

ply

176

9 I/O

176

9 En

d Cap

20D-

DL

2-CR2

17

69 I/

O

Bank 1

I/O Slot Number

Driv

eL

og

ix

Pow

er

Fle

x 700S 

D

riv

e

176

9 Po

wer

 Supp

ly

1769

 I/O

17

69-

CRl

3

20D

-DL

2-

CR2

1769

 I/O

Bank 1

I/O Slot Number

2

1

2

1

1769

 Pow

er

 Su

pply

17

69 I

/O

17

69 E

nd Cap

176

9-CRl3

1769 I/O

Bank 2

4

3

Allen-Bradley Motors

Summary of Contents for DriveLogix5730

Page 1: ...Instructions Compact I O Cable for DriveLogix5730 Controller Cat No 20D DL2 CR3 20D DL2 CL3 Inside For More Information 2 Hazardous Location Considerations 3 Overview 4 Cable Types and Length 4 Syste...

Page 2: ...Discrete Compact I O module 1769 OA8 Compact 1769 OA8 100 to 240V ac Solid State Output Module Installation Instructions 1769 IN055 Installation guides for 1769 Discrete Compact I O module 1769 OV16 C...

Page 3: ...unless power has been switched off or the area is known to be non hazardous Do not connect or disconnect components unless power has been switched off or the area is known to be non hazardous All wiri...

Page 4: ...to end of the cable only 20D DL2 CL3 Controller to left bank expansion 3 28 ft 1 m 20D DL2 CR3 Controller to right bank expansion 3 28 ft 1 m 15 mm 0 59 in 32 mm 1 26 in 18 mm 0 71 in 118 mm 4 65 in...

Page 5: ...769 CRL3 1769 CRL3 1769 I O 1769 Power Supply 1769 I O 1769 End Cap 20D DL2 CL2 1769 I O 1769 Power Supply PowerFlex 700S Drive DriveLogix 1 I O Slot Number 2 3 4 20D DL2 CL2 DriveLogix PowerFlex 700S...

Page 6: ...An electrical arc can cause personal injury or property damage by sending an erroneous signal to your system s field devices causing unintended machine motion causing an explosion in a hazardous envir...

Page 7: ...to Do Step 1 Remove power from drive and Compact I O Step 2 Remove the control cassette from the drive and the cover from the control cassette Step 3 Install the controller end of the cable Step 4 Re...

Page 8: ...ck The voltage must be zero Remove power before making or breaking cable connections When you remove or insert a cable connector with power applied an electrical arc may occur An electrical arc can ca...

Page 9: ...x3 A B Proper tightening torque for reassembly is 6 lb in Removing the Cassette Task Description Open the door of the power structure and disconnect the cables that connect to the main board Loosen sc...

Page 10: ...on Install clips on controller end of cable Plug controller end of cable into mating connector on the Logix Expansion Board Install and tighten screws 6 lb in Route and secure cable A B C D Step 4 Rep...

Page 11: ...2 3 A D 1 B C E 1 C B 2 3 Left Cover Right Cover Task Description Unlock the Bus Lever on the I O module accepting the cable cover by pushing the lever back and then right Align both of the cable cove...

Page 12: ...om Corporate Headquarters Rockwell Automation 777 East Wisconsin Avenue Suite 1400 Milwaukee WI 53202 5302 USA Tel 1 414 212 5200 Fax 1 414 212 5201 Headquarters for Allen Bradley Products Rockwell So...

Reviews: