        Compact I/O Cable for DriveLogix5730 Controller     

Publication 20D-IN008A-EN-P - April 2004

 

 

 

Installation

Remove Power

To avoid an electric shock hazard, verify that the voltage on the bus 
capacitors has discharged before performing any work on the drive. 
Measure the DC bus voltage at the +DC & –DC terminals of the 
Power Terminal Block. The voltage must be zero.

HOT surfaces can cause severe burns. Do not touch the heatsink 
surface during operation of the drive. After disconnecting power 
allow time for cooling.

Remove power before making or breaking cable connections. When 
you remove or insert a cable connector with power applied, an 
electrical arc may occur. An electrical arc can cause personal injury or 
property damage by:

sending an erroneous signal to your system’s field devices, 
causing unintended machine motion

causing an explosion in a hazardous environment

Electrical arcing causes excessive wear to contacts on both the 
module and its mating connector. Worn contacts may create electrical 
resistance.

Electrostatic discharge can damage integrated circuits or 
semiconductors if you touch bus connector pins or the terminal 
block. Follow these guidelines when handling 1769 Compact I/O 
components:

Touch a grounded object to discharge static potential.

Wear an approved wrist-strap grounding device.

Do not touch the bus connector or connector pins.

Do not touch circuit components inside the module.

If available, use a static-safe workstation.

When not in use, keep cables in static shield packaging.

ATTENTION

!

Summary of Contents for DriveLogix5730

Page 1: ...Instructions Compact I O Cable for DriveLogix5730 Controller Cat No 20D DL2 CR3 20D DL2 CL3 Inside For More Information 2 Hazardous Location Considerations 3 Overview 4 Cable Types and Length 4 Syste...

Page 2: ...Discrete Compact I O module 1769 OA8 Compact 1769 OA8 100 to 240V ac Solid State Output Module Installation Instructions 1769 IN055 Installation guides for 1769 Discrete Compact I O module 1769 OV16 C...

Page 3: ...unless power has been switched off or the area is known to be non hazardous Do not connect or disconnect components unless power has been switched off or the area is known to be non hazardous All wiri...

Page 4: ...to end of the cable only 20D DL2 CL3 Controller to left bank expansion 3 28 ft 1 m 20D DL2 CR3 Controller to right bank expansion 3 28 ft 1 m 15 mm 0 59 in 32 mm 1 26 in 18 mm 0 71 in 118 mm 4 65 in...

Page 5: ...769 CRL3 1769 CRL3 1769 I O 1769 Power Supply 1769 I O 1769 End Cap 20D DL2 CL2 1769 I O 1769 Power Supply PowerFlex 700S Drive DriveLogix 1 I O Slot Number 2 3 4 20D DL2 CL2 DriveLogix PowerFlex 700S...

Page 6: ...An electrical arc can cause personal injury or property damage by sending an erroneous signal to your system s field devices causing unintended machine motion causing an explosion in a hazardous envir...

Page 7: ...to Do Step 1 Remove power from drive and Compact I O Step 2 Remove the control cassette from the drive and the cover from the control cassette Step 3 Install the controller end of the cable Step 4 Re...

Page 8: ...ck The voltage must be zero Remove power before making or breaking cable connections When you remove or insert a cable connector with power applied an electrical arc may occur An electrical arc can ca...

Page 9: ...x3 A B Proper tightening torque for reassembly is 6 lb in Removing the Cassette Task Description Open the door of the power structure and disconnect the cables that connect to the main board Loosen sc...

Page 10: ...on Install clips on controller end of cable Plug controller end of cable into mating connector on the Logix Expansion Board Install and tighten screws 6 lb in Route and secure cable A B C D Step 4 Rep...

Page 11: ...2 3 A D 1 B C E 1 C B 2 3 Left Cover Right Cover Task Description Unlock the Bus Lever on the I O module accepting the cable cover by pushing the lever back and then right Align both of the cable cove...

Page 12: ...om Corporate Headquarters Rockwell Automation 777 East Wisconsin Avenue Suite 1400 Milwaukee WI 53202 5302 USA Tel 1 414 212 5200 Fax 1 414 212 5201 Headquarters for Allen Bradley Products Rockwell So...

Reviews: