16
Rockwell Automation Publication 2711P-IN026H-EN-P - May 2018
High-bright Display Modules
2. Gently pull the terminal block away from the connector.
Follow these steps to install the terminal block.
1. Reattach the terminal block to the connector until seated.
2. Tighten the two screws that secure the terminal block to the connector.
DC Power Connections
DC-powered PanelView Plus devices have an integrated 24V DC power supply. Both isolated
and nonisolated power supplies have these ratings:
• 24V DC nominal (18…32V DC)
• 70 W maximum (2.9 A at 24V DC)
The power supply is internally protected against reverse polarity of the DC+ and DC-
connections.
The input power terminal block supports these wire sizes.
Wire Specifications for DC Input Power Terminal Block
Attribute
Value
Wire Type
Stranded or solid,
Cu 90 °C (194 °F)
Dual-wire Gauge
(1)
(1)
Two-wire max per terminal.
22…16 AWG
Single-wire Gauge
22…14 AWG
Terminal Screw Torque
Logic module, series A to D
Logic module, series E and later
0.23…0.34 N•m (2…3 lb•in)
0.56 N•m (5 lb•in)
Two-position Terminal Block
(Series E or later logic module)
Three-position Terminal Block