Allen-Bradley 2711P-RDT12H Installation Instructions Manual Download Page 1

Installation Instructions

Original Instructions

High-bright Display Modules

Catalog Number 2711P-RDT12H

Topic

Page

Important User Information

2

Summary of Changes

3

About the Module

3

Environment and Enclosure

4

Outdoor Installation

4

Hazardous Locations

5

Environnements dangereux

6

Wiring and Safety Guidelines

8

About the Terminals

9

Install the Terminal

9

Logic Module Compatibility

13

External Power Supply For Nonisolated DC Terminals

13

External Power for Isolated DC Terminals

14

Remove and Install the Power Terminal Block

15

DC Power Connections

16

Ethernet Cable

17

Troubleshooting

18

Specifications

20

Additional Resources

22

Summary of Contents for 2711P-RDT12H

Page 1: ...Installation 4 Hazardous Locations 5 Environnements dangereux 6 Wiring and Safety Guidelines 8 About the Terminals 9 Install the Terminal 9 Logic Module Compatibility 13 External Power Supply For Non...

Page 2: ...th respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automati...

Page 3: ...module in a panel or enclosure Refer to the installation instructions shipped with the logic module and communication module for field installation of these components For complete information on ins...

Page 4: ...maintain internal temperatures within specification ATTENTION This equipment is intendedfor useinaPollutionDegree 2industrial environment in overvoltage Category II applications as defined in IEC publ...

Page 5: ...decrease the display intensity by using the screen saver with a 5 10 minute delay Avoid placing the terminal on the south north in the southern hemisphere or west side of the cabinet if possible This...

Page 6: ...ts contenant des gaz atmosph riques inflammables moins de 135 C 275 F USBPorts The terminals contain universal serial bus USB ports that comply with hazardous location environments This section detail...

Page 7: ...for them to remain nonincendive when used with the PanelView Plus 700 to 1500 USB port If cable capacitance and inductance are not known the following values from ANSI ISA RP 12 06 01 2003 may be use...

Page 8: ...mendations refer to the National Electrical Code published by the National Fire Protection Association For more information refer to Wiring and Grounding Guidelines for PanelView Plus Devices Technica...

Page 9: ...uctions shipped with each module PartsList These items are shipped with the terminals Power terminal block Mounting clips FactoryTalk View software preloaded Installation instructions and panel cutout...

Page 10: ...outDimensions Use the full size template shipped with your terminal to mark the cutout dimensions The 1250 Touch PanelView Plus PanelView Plus CE and PanelView Plus 6 Terminals are 257 mm 10 11 in hig...

Page 11: ...on the terminal This gasket forms a compression type seal Do not use sealing compounds 3 Place the terminal in the panel cutout 4 Slide the ends of the mounting clips into the slots on the terminal 5...

Page 12: ...igh bright display module Depth dimensions are shown for base configured unit display module and logic module base configured unit with communication module Measurements are in mm in ATTENTION Tighten...

Page 13: ...escription PanelView Plus 700 to 1500 Logic Modules 2711P RP2 Logic module with 128 MB flash 128 MB RAM DC input PanelView Plus CE 700 to 1500 Logic Modules 2711P RP6 PanelView Plus CE logic module wi...

Page 14: ...DC logic modules are identified by catalog number 2711P RPxDx ATTENTION UseanSELVorPELVsupplyasrequiredbylocalwiringcodesforyourinstallation The SELV and PELV power sources provide protection so that...

Page 15: ...llow these steps to remove the terminal block 1 Loosen the two screws that secure the terminal block ATTENTION Damage or malfunction can occur when a voltage potential exists between two separate grou...

Page 16: ...es have these ratings 24V DC nominal 18 32V DC 70 W maximum 2 9 A at 24V DC The power supply is internally protected against reverse polarity of the DC and DC connections The input power terminal bloc...

Page 17: ...hernetCable For PanelView Plus 700 to 1500 terminals use Belden 7921A shielded Ethernet Category 5e cable according to TIA 568 B 1 and RJ45 connector according to IEC 60603 7 for compliance with the E...

Page 18: ...wer requirements in the Specifications table CheckStatusIndicators The terminal has two status indicators to isolate operating problems COMM indicator green for communication FAULT indicator red for h...

Page 19: ...bright display module has a built in temperature sensor that automatically reduces the backlight intensity if the temperature inside the cabinet exceeds 55 C 131 F Indicator States if the Terminal Sto...

Page 20: ...00 x 600 Luminance 1000 cd m2 Nits Backlight Not replaceable Touch screen Analog resistive Electrical Input voltage DC 24V DC nom 18 32V DC Power consumption DC 70 W max 2 9 A 24V DC Mechanical Dimens...

Page 21: ...ertification 1 1 See the Product Certification link on https ab rockwellautomation com fordeclarations of conformity certificates and othercertification details 2711P RDT12H c UL us UL Listed Industri...

Page 22: ...iew Plus CE terminalsandgivesinformationonhowtoinstall operate configure and troubleshoot these devices PanelViewPlus6TerminalsUserManual publication 2711P UM006 Provides instructions on how to instal...

Page 23: ...Rockwell Automation Publication 2711P IN026H EN P May 2018 23 High bright Display Modules Notes...

Page 24: ...ockwell Automation maintains current product environmental information on its website at http www rockwellautomation com rockwellautomation about us sustainability ethics product environmental complia...

Reviews: