To verify that the example programs above are executing properly, follow
these steps:
1.
Look at the PLC-5 (node 51 octal) file contents of integer file 7 by
typing:
<DISPLAY MONITOR> N7:0
2.
Change any value in word locations 0 through 7 in this file.
3.
These values in word locations 10 through 17 should be the same as
the values in word locations 0 through 7.
Important:
These PLC5 to PLC5 examples are for testing only. Toggling
the continuous bit to ON generates high network traffic which, in most
cases, is not necessary.
A*::.-0(8*'&(1"#-(C-&(AI!5)(*-(#(=#%#(>.0"?#@(A:,B
Since the 1785-KE Series B is transparent to the master, remote PLC-5’s
can be polled as individual slaves whether there is one or multiple PLC-5’s
attached to a given 1785-KE. As a result, PLC-5’s on a remote DH + can
be polled as though they were individual slave stations. Figure 5.5
illustrates this application.