Reference Manual
Bulletin 1606 Switched Mode Power Supplies
Catalog Number: 1606-XLE480FP
Index
e
g
a
P
e
g
a
P
1.
Intended Use .......................................................3
2.
Installation Requirements...................................3
3.
AC-Input...............................................................4
4.
DC-Input...............................................................5
5.
Input Inrush Current ...........................................5
6
.
Output .................................................................
6
7.
Hold-up Time.......................................................8
8.
DC-OK Relay Contact ..........................................8
9.
Efficiency and Power Losses................................9
10.
Lifetime Expectancy and MTBF.........................10
11.
Functional Dia
g
ram...........................................10
12.
Terminals and Wirin
g
........................................11
13.
Front Side and User Elements...........................12
14.
EMC....................................................................13
15.
Environment ......................................................14
1
6
.
Protection Features ...........................................15
17.
Safety Features ..................................................15
18.
Dielectric Stren
g
th ............................................1
6
19.
Certifications......................................................1
6
20.
Physical Dimensions and Wei
g
ht ..................... 17
21.
Accessories ........................................................ 18
21.1.
1
6
0
6
-XLC Wall Mountin
g
Bracket......... ...18
22.
Application Notes............................................. 19
22.1.
Peak Current Capa
b
ility ...........................19
22.2.
Back-feedin
g
Loads ..................................19
22.3.
External Input Protection .........................20
22.4.
Output Circuit Breakers ............................20
22.5.
Parallel Use to Increase Output Power ....21
22.
6
.
Parallel Use for Redundancy ....................21
22.7.
Series Operation .......................................22
22.8.
Inductive and Capacitive Loads ................22
22.9.
Char
g
in
g
Batteries ....................................23
22.10.
Operation on Two Phases ........................23
22.11.
Use in a Ti
g
htly Sealed Enclosure ............23
22.12.
Mountin
g
Orientations ............................24
• PE and
symbol—
PE is the abbreviation for
P
rotective
E
arth and has the same meaning as the symbol
.
• Earth, Ground—
This document uses the term “earth” which is the same as the U.S. term “ground”.
• T.b.d.—
To be defined, value or description will follow later.
• 3AC 400V—
A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%)
included. E.g.: DC 12V describes a 12V battery whether it is charged (13.7V) or discharged (10V).
• 230Vac—
Afigure with the unit (Vac) at the end is a momentary figure without any additional tolerance included.
• 50Hz vs. 60Hz—
Unless otherwise stated, AC 230V parameters are valid at 50Hz mains frequency.
• may—
A key word indicating flexibility of choice with no implied preference.
• shall—
A key word indicating a mandatory requirement.
• should—
A key word indicating flexibility of choice with a strongly preferred implementation.
Terminology and Abbreviations