2.

 

Front Panel 

 

 

 

 

  

Input sockets

 

 Balanced XLR mic/line inputs with +48V Phantom Power 

indicator. The preamps are built into the GX4816 and their Gain, Pad and +48V are 

controlled from the mixer via the Cat5 link.  

The +48V indicator detects voltage at the socket whether supplied by the GX4816 or 

received from an external source. 

  

Output sockets

 

 Balanced XLR outputs operating at n4dBu level. 

  

Mains power

 

 IEC connector and power switch for the built-in universal 

voltage  PSU.  This  accepts  voltages  from  100  to  240V  AC. Secure  the  cable  to  the 

plastic P-clip using a T20 screwdriver. 

 Heed the safety warnings printed on the panel.  

  

Status indicators

 

 The 

Ready 

indicator lights up when the output sockets 

are ready to pass audio after power up. 

Power

 indicates the correct functioning of the 

PSU. 

  

GX port

 

 EtherCon port for connection to the mixing system over Gigabit 

Ethernet. A single Cat5e (or higher) cable carries multichannel audio at 96kHz and 

control.  

   

DX  ports

 

  EtherCon  ports  for  connection  of  DX  Expanders  over  Fast 

Ethernet. Each cable carries 32x32 channels of 96kHz audio and control. Connect a 

single DX32, or up to 2x DX168 / DX164-W per port. 

 DX1 and DX2 on this device cannot be used for redundancy 

purposes.  

 When connected to a ME-U, ME-1 or ME-500, the 

DX2

 port is 

self-configured as a 40ch, 48kHz output only port for the ME 

personal mixing system. Channel names and stereo links are 

communicated to connected ME systems, and the ME output 

patch temporarily replaces the output patch to the DX2 port. 

 

 

Summary of Contents for GX Series

Page 1: ...GX Expander Getting Started Guide GX4816 Before starting please check www allen heath com for the latest mixer firmware and product documentation AP11651 ...

Page 2: ...th website www allen heath com legal Repair or replacement under the terms of the warranty does not provide right to extension or renewal of the warranty period Repair or direct replacement of the product under the terms of this warranty may be fulfilled with functionally equivalent service exchange units This warranty is not transferable This warranty will be the purchaser s sole and exclusive re...

Page 3: ...ee www allen heath com legal Further information Please refer to the Allen Heath website for further information knowledgebase and technical support For more information on mixer setup and mixing functions please refer to the mixer Firmware Reference Guide available for download at www allen heath com Check for the latest version of this Getting Started Guide General precautions Protect the equipm...

Page 4: ...ine outputs as well as 2 DX ports for further system expansion or connection to the ME personal mixing system The GX4816 connects to the mixer over a single Cat5e cable Contents IMPORTANT Read before starting 3 Packed items 4 Introduction 4 Contents 4 1 Installing the Expander 5 1 1 Free standing 5 1 2 Rack mounting and flight casing 5 1 3 Rack ears 5 2 Front Panel 6 3 Rear Panel 7 4 Connect and p...

Page 5: ... other portable use we recommend that you use a professional grade flight case Ensure natural convection of airflow around the unit by allowing good ventilation below in front of and behind the unit Rack equipment known to produce a significant amount of heat should not be mounted directly below the unit Forced convection by means of a rack mounted fan tray may be desirable in situations where spa...

Page 6: ...ators The Ready indicator lights up when the output sockets are ready to pass audio after power up Power indicates the correct functioning of the PSU GX port EtherCon port for connection to the mixing system over Gigabit Ethernet A single Cat5e or higher cable carries multichannel audio at 96kHz and control DX ports EtherCon ports for connection of DX Expanders over Fast Ethernet Each cable carrie...

Page 7: ... Ensure good ventilation and avoid obstruction of vents while operating Avoid dirt or liquid ingress Fan Ultra quiet fan Make sure the ventilation opening is not obstructed Kensington Lock A slot for fitting standard Kensington anti theft security devices 1 2 3 3 1 2 ...

Page 8: ... the same version as that in the mixer then the mixer will automatically update the GX firmware during power up This can take up to 20 seconds During this time the Lnk Err indicators on the GX Expander flash at a fast rate Once updated normal flash rate is restored 4 2 DX Expander connection Connect a single DX32 or up to 2x DX168 DX164 W per DX port DX Expander inputs will appear as inputs 65 96 ...

Page 9: ...GX4816 Getting Started Guide 9 AP11651 Issue 1 5 Dimensions 390 00mm 15 3 183 80mm 7 2 229 50mm 9 0 441 00mm 17 4 100 1mm 4 481 60mm 18 9 221 50mm 8 7 255 0mm 10 115 60mm 4 6 ...

Page 10: ...AD Residual Output Noise 95dBu muted 22Hz 22kHz Maximum Input Level 30dBu PAD in Input Impedance 4kΩ Pad out 10kΩ Pad in Mic EIN 127dB with 150Ω source Phantom Power indication Per socket internal or external phantom power sensing triggered at 24V Power Temperature Mains Voltage Operating Range 100 240V AC 50 60Hz Operating Temperature Range 0 C to 40 C 32 F to 104 F Mains Power Consumption 80W ma...

Reviews: