background image

READER CONNECTION 

 
The Protégé Reader Expander allows the connection of 4 
Wiegand reading devices and the ability to control 2 
doors (Entry or Exit Only) or 1 door (Entry and Exit). The 
following diagrams show the connection of standard 
Wiegand Reader (Entry Unit) and a Multiplexed reader 
(Exit Reader). 

 

 

When operating the reader expander in multiple reader 
mode the Protégé Reader Expander allows the 
connection of 4 wiegand reading devices controlling two 
doors each with Entry/Exit readers.  

 
DOOR CONTACT CONNECTION 

 
The Protégé Reader Expander allows the connection of 
up to 4 contacts for monitoring and controlling access 
control doors. Each zone on 
the reader expander can be 
used for the door function 
that is automatically 
assigned and as a normal 
zone input on the system. 
The following example 
shows the connection of a 
normally closed door 
position monitoring contact 
to monitor the open, closed, 
forced and alarm conditions 
of the door. 

 

 

DOOR LOCK CONNECTION 

 
The Protégé Reader expander provides a connection for 2 
electric strike locks with full monitoring of the lock circuit 
for tamper and over current/fuse blown conditions. The 
door lock monitoring can be disabled if it is not required.  

 

 

 
SPECIFICATION 

 
Power Supply 

AC Input Voltage 

16VAC 50/60Hz @ 40VA (Max) 

Operating Current 

280mA (Typical) 

DC Output (Auxiliary)  1.2A (Max) 
Battery Charging 

350mA/700mA  

Communication 

RS-485 

 

Isolated Module Network   

Outputs 

Lock Outputs   

2 Outputs 

 

   400mA 

(Max), 

500mA 

Shutdown 

PGM Outputs   

6 (50mA Max) Open Collector 

Inputs 

Zone  

 

8 (500ms to 40sec Input Speed) 

Tamper 

 

1 (Normally Closed) 

Trouble Zone   

16 

Dimensions 

PCB Dimensions 

183mm X 234mm 

   7.2" 

9.2" 

 
*Specifications are subject to change without notice, please 
visit www.integratedcontroltechnology.com for the updated 
information.  

 

 

 

Unit C, 6 Ascension Place, Mairangi Bay, P.O. Box 302-340 

North Harbour, Auckland, New Zealand. 

Phone: +64 (9) 476 7124  

y

  Fax: +64 (9) 476 7128 

www.integratedcontroltechnology.com 

 

 

 

2 Reader Expander 

Quick Start Guide 

 

 

 

PRT-RDI2 / RDS2  

 

 
 
 
INTRODUCTION 

 
The Protégé Reader Expander extends the number of card 
reader inputs on the system by 2, number of zone inputs 
by 8 (4 zones used for door monitoring  and control and 
up to eight can be used for extended functionality) and 
the number of PGM outputs by 8 (includes 2 monitored 
lock control outputs). 

 

 

4 Wiegand Reader Mode for 2 Entry/Exit Doors Per 
Reader Expander 

 

Secure Encrypted RS-485 Module Communications 

 

8 Zone Inputs 

 

2 Monitored Lock Control PGM Outputs  

 

6 Open Collector PGM Outputs (Reader Control 
Outputs) 

 

Intelligent Battery Charge and Monitoring  

 

Smart Reader Missing/Tamper Monitoring 

 

Online and Remote upgradeable firmware 

 
For a full installation manual or more information on the 
Protégé Reader Expander and other Integrated Control 
Technology products please login to our website 
www.integratedcontroltechnology.com 