background image

3

DIP Switch/Jumper Setting

The DIP switch/jumper on the SMR10/20 readers are used to select a preset 
format. This preset format determines how the card is interpreted, the functions 
for the LED and buzzer, and the output signal format, etc. Refer to the format 
specification for detail. The settings are for STANDARD models ONLY.

Format

Switch

Output

LED

Buzzer Tamper

4

3

2

1

0

on

on

on

on

DATA1/DATA 0

1-WIRE

yes

no

1

on

on

on

off

CLOCK/DATA

1-WIRE

yes

no

2

on

on

off

on

CLOCK/DATA

1-WIRE

yes

yes

3

on

on

off

off

CLOCK/DATA

1-WIRE

yes

no

4

on

off

on

on

DATA 1/DATA 0

1-WIRE

yes

no

5

on

off

on

off

DATA 1/DATA 0

1-WIRE

yes

no

6

on

off

off

on

DATA 1/DATA 0

1-WIRE

yes

no

7

on

off

off

off

DATA 1/DATA 0

1-WIRE

yes

no

12

off

off

on

on

CLOCK/DATA

2-WIRE

no

no

13

off

off

on

off

DATA 1/DATA 0

2-WIRE

no

no

15

off

off

off

off

CLOCK/DATA

1-WIRE

yes

yes

SMR10/20 Standard Format Code Summary

The following formats are supported in standard models (300x2-0000/310x2-0000).Unless otherwise indicated, the LED input 
line controls both LEDs (low=green, high=red); the BUZZER input controls the buzzer (low = activate); a good read is signaled 
by a flash of the green LED; a bad read is signaled by a flash of the red LED and a double beep of the buzzer.

Format

Description

0

32-bit Wiegand compatible output from standard 
Northern Computer mag card. 16-bit facility code and 
16-bit user ID. Reverse read and error filter is enabled. 
Tamper monitor disabled.

1

Basic mag-stripe data output: send track 2 data without 
any verification or formatting using CLOCK/DATA 
signaling. (All reads are “good”, card data is sent  as is.) 
Tamper monitor disabled.

2

Mag-stripe data output with zero trim using CLOCK/DATA 
signaling. (All reads are “good”, trims excess zero bits, 
otherwise sends data as is.) Tamper monitor enabled.

3

Mag-stripe data output with zero trim, reverse read 
correction, and error filter enabled using CLOCK/DATA 
signaling.  Tamper monitor disabled.

4

26-bit Wiegand (8-bit fac. and 16-bit ID) compatible 
output from cards with 8 or more digits  or AMC 
encoding. See 

Digit Usage

 on page 3 for more 

information. Tamper monitor disabled

5

34-bit Wiegand (12-bit fac. and 20-bit ID) compatible 
output from cards with 8 or more digits or AMC encoding.  
See 

Digit Usage

 on page 3 for more information. Tamper 

monitor disabled.

Format

Description

6

26-bit Wiegand compatible output from standard 
Northern Computer 32-bit mag-stripe card. The lower 8 
bits of the 16-bit facility code is used as facility code. The 
16-bit user ID is unaltered. Reverse read and error filter 
is enabled.  Tamper monitor disabled.

7

Mag-stripe data output with zero trim and reverse read 
correction using DATA 1/DATA 0 signaling. Tamper 
monitor disabled.

12

Mag-stripe data output using CLOCK/DATA signaling. 
2-wire LED control. No buzzer control. Tamper 
monitor disabled.

13

Mag-stripe data output using DATA 1/DATA 0 signaling. 
2-wire LED control. No buzzer control. Tamper monitor 
disabled.

15

(factory test) mag-stripe data output: verify track 2 data 
and send track 2 data without formatting using CLOCK/
DATA signaling. Zero trim, reverse read, bad card filter, 
and tamper monitor option are enabled.

Digit Usage

Facility Code

User ID

Digits in mag card

Digits

26-bit  Range

34-bit Range

Digits

26-bit Range

34-bit Range

8

1-3

000-255

000-999

4-8

00000-65535

00000-99999

9

1-3

000-255

000-999

4-9

000000-065535

000000-999999

10

1-4

0000-0255

0000-4097

5-10

000000-065535

000000-999999

11 or more

1-5

00000-00255

00000-04097

6-11

000000-065535

000000-999999

AMC card

1-6

000000-000255

000000-004097

7-12

000000-065535

000000-999999

4 3

2 1

Handmade Tool

Highlighted states are 
compatible with the 
CT5000 or the WRI.

Summary of Contents for Schlage SMR-10

Page 1: ...on box is used a wall plate optional may be used to cover the junction box The reader is then secured to the mounting bracket using a screw Refer to figures for reader dimensions and typical junction...

Page 2: ...not use sealant to seal reader case to the wall Doing so will trap water in the reader and may cause damage to the reader TTL Interface The TTL interface has the standard 5 wire interface widely used...

Page 3: ...zero bits otherwise sends data as is Tamper monitor enabled 3 Mag stripe data output with zero trim reverse read correction and error filter enabled using CLOCK DATA signaling Tamper monitor disabled...

Page 4: ...ill flash Otherwise the red LED will flash and the buzzer will sound two short beeps to indicate an error The LED input can be used to verify the LED function and the buzzer input for the buzzer funct...

Page 5: ...mension 1 95 50mm W x 1 30 33mm H x 5 50 140mm L Weight 10 oz 284 g nominal Material Case Die cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standa...

Page 6: ...l Wall Plate part WP10 6 30 160 3 30 84 1 38 35 1 23 31 1 40 36 4 00 102 2X 0 18 4 5 2 75 70 Fitting Rigid Conduit to Junction Box WALL OPENING FOR J BOX Rigid Conduit 1 Gang Box WALL STUD Wall Openin...

Page 7: ...and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns m...

Page 8: ...Allegion 2017 Printed in U S A 23884539 Rev 08 17 b...