background image

5

Specification

The reader is for use in low voltage, class 2 circuits only.

Power

Voltage

5Volt Model: 5.8 Vdc (4.9 to 6.4 Vdc) 
12Volt Model: 12 Vdc (10.2 to 13.8 Vdc)

Current 

50mA (25mA typical.)

Data output

Data 1/0 pair or clock/data
Timing

clock/data

period 1mS 
setup/hold time 400uS, clock pulse width 200uS typical

data 1/0

period, 1mS for Wiegand data, 1mS for mag stripe data 
pulse width 50uS typical

LED input

1-wire mode

input not driven: LEDs off 
input > 3.5Vdc: Red LED on 
input < 0.8Vdc: Green LED on

2-wire mode input < 0.8Vdc: Red LED on

Buzzer/LED

1-wire mode

input not driven or > 3.5Vdc: buzzer off 
input < 0.8Vdc: buzzer on

2-wire mode input < 0.8Vdc: Green LED on

Mechanical

Dimension

1.95” (50mm) W x 1.30” (33mm) H x 5.50” (140mm) L

Weight

10 oz. (284 g) nominal

Material

Case, Die cast aluminum, gray powder coat standard. 
Mounting, stainless steel 
Wall plate, 18 CRS, gray powder coat standard

Car

75 bpi, ANSI X4.16, Track 2 standard, Speed 3 to 50 ips

Read Head

1,000,000 passes typical, standard.

Distance

500’ (152m) with 18 AWG wires.

Environmental Temperature

-55 to +85 degrees C, storage 
-40 to +75 degrees C, operating

Humidity

0-95% RHNC, standard 
100% (-OW option)

Product Identification

Reader product identification is provided on labels. These labels have information on program ID, revision, product ID, supply 
voltage, and copyright notice. These labels are located on the circuit board and the back of the reader.

Program ID
Serial No.
Copyright

Manual revision, see appropriate 
manual for FORMAT information

Highlighted states are 
compatible with the 
CT5000 or the WRI.

Summary of Contents for Schlage SMR-10

Page 1: ...on box is used a wall plate optional may be used to cover the junction box The reader is then secured to the mounting bracket using a screw Refer to figures for reader dimensions and typical junction...

Page 2: ...not use sealant to seal reader case to the wall Doing so will trap water in the reader and may cause damage to the reader TTL Interface The TTL interface has the standard 5 wire interface widely used...

Page 3: ...zero bits otherwise sends data as is Tamper monitor enabled 3 Mag stripe data output with zero trim reverse read correction and error filter enabled using CLOCK DATA signaling Tamper monitor disabled...

Page 4: ...ill flash Otherwise the red LED will flash and the buzzer will sound two short beeps to indicate an error The LED input can be used to verify the LED function and the buzzer input for the buzzer funct...

Page 5: ...mension 1 95 50mm W x 1 30 33mm H x 5 50 140mm L Weight 10 oz 284 g nominal Material Case Die cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standa...

Page 6: ...l Wall Plate part WP10 6 30 160 3 30 84 1 38 35 1 23 31 1 40 36 4 00 102 2X 0 18 4 5 2 75 70 Fitting Rigid Conduit to Junction Box WALL OPENING FOR J BOX Rigid Conduit 1 Gang Box WALL STUD Wall Openin...

Page 7: ...and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns m...

Page 8: ...Allegion 2017 Printed in U S A 23884539 Rev 08 17 b...

Reviews: