background image

 

 

Summary of Contents for Interflex IF-171

Page 1: ......

Page 2: ......

Page 3: ...his manual which is subject to change without prior notice Interflex Datensysteme GmbH does not enter into any commitment Copyright 2016 Version September 23 2016 Interflex Datensysteme GmbH Allegion...

Page 4: ...oor handle Please thoroughly read through this operating and assembly manual to ensure failure free and secure operations Please adhere to all notes included therein before you start operating door ha...

Page 5: ...dards effective at the time of printing Device modifications are not permitted All technical information herein is accurate at the time of printing It is however not to be deemed in any way to be a sp...

Page 6: ......

Page 7: ...9 2 2 3 Assembly of the Square Pin 9 2 2 4 Design for Door with Electronic Authorization on One Side 10 2 2 5 Design for Door with Electronic Authorization on Both Sides 12 2 2 6 Assembling the Key R...

Page 8: ...g deactivating the permanently open mode 29 3 5 3 Automatically blocking unblocking a door 30 4 Attachment 31 4 1 Applicable Reading Technologies 31 4 2 Possible Data Formats and Required Memory Capac...

Page 9: ...tion Escape and Emergency Escape Routes Fire doors escape and emergency escape routes that are restricted in their functions can result in life threatening situations When you install devices and conf...

Page 10: ...ions Adhere to all provisions for lithium batteries that are applicable to your area e g provisions concerning the storage transport of hazardous goods packaging provisions for air transport protectio...

Page 11: ...ounding during activities when sitting e g wrist grounding strap Where this is not possible e g product already installed at least touch a grounded item in order to conduct electrostatic charge away f...

Page 12: ......

Page 13: ...doors as well as doors with narrow frames having a backset of more than 30 mm Figure IF 171 with round rosette 2 1 Product Description IF 171 The reading unit the communication electronics the mechan...

Page 14: ...is below certain values three level signaling As a result you will be informed in sufficient time that a battery replacement is due We recommend changing the battery once the third stage is displayed...

Page 15: ...2 Locking screw 8 Reading unit 3 Mounting screw 9 Battery 4 Adapter sleeve only for 7 mm square pin 10 Gripping sleeve 5 Handle holder with bayonet lock 11 Grub screw for gripping sleeve 6 Square pin...

Page 16: ...utside version 2 Electronic door handle only for two sided electronic authorization incl rosette sealing ring only with outside version 3 Drilling template 4 2mm Allen key 1 per order 5 Optional Key r...

Page 17: ...not protrude thus preventing the door from swinging freely Before assembling the door handle always check the freedom of movement of all components After assembly check the function with the door open...

Page 18: ...ock Slip drilling template onto the square pin Align the drilling template horizontally Mark the holes Remove the square pin Drill holes of diameter 8 8 5 mm at the marked positions Do not drill into...

Page 19: ...yonet lock snap into place Tighten the rosette towards the right for door handles pointing to the left Screw the locking screw in at the bottom of the rosette Tighten the screw Insert the battery to o...

Page 20: ...marked positions Do not drill into or through the lock housing Insert the square pin of the electronic door handle back into the square nut of the lock If necessary place the adapter sleeve supplied o...

Page 21: ...r handle with the door open To do this hold an authorized credential in front of the reading unit When engaged the catch of the lock should be completely inside the lock housing when the latch is pres...

Page 22: ...re using LEGIC credentials the devices must additionally read the LEGIC SAM card Management Basically there are two options for managing and parameterizing the devices Managing the devices in the acce...

Page 23: ...or time dependent access restrictions The time is also set during the door initialization For this purpose a door specific door initialization card must be written Switchover to daylight saving time l...

Page 24: ...ntial with standard function and permanently open function GREEN GREEN long RED Signaling for a credential that only has the permanently open function Long RED Booking memory entry Toggle closed In th...

Page 25: ...moved See also Important Instructions and Guidelines regarding Batteries 2 Maintenance Always with Open Door 2 Electrostatic Discharge ESD 2 2 5 2 Replacing the Sealing Ring The sealing ring may be da...

Page 26: ...natural atmospheric exposure corrosion Do not use screws that were made of or are anodized with less noble metals as fasteners Stainless steel products must be cleaned at regular intervals if you want...

Page 27: ...the square pin Tighten the rosette correspondingly towards the right for door handles pointing to the left Unscrew in the handle holder Pull the electronic door handle from the lock Disassembly for D...

Page 28: ...the square pin from the fixture Remove adapter sleeve from square pin fixture if required 2 6 2 Disposal Once its service life comes to an end the device must be disposed of properly as electronic was...

Page 29: ...ocation Indoor installation Protection category IP20 Standards Standards and Regulations The electronic IF 171 door handle meets the following standards and regulations EN 300 220 V2 4 1 EN 302 291 V1...

Page 30: ...22 The Electronic IF 171 Door Handle U Shape electronic Side U Shape Mechanical Side...

Page 31: ...ir first booking at such a terminal If such a credential is lost this means that already on the following day bookings can no longer be performed with this credential at NetworkOnCard readers Furtherm...

Page 32: ...ange System IF 60x0 Generates the data to be transferred to the NoC readers offline devices Reads data from the NoC readers this includes e g the bookings performed at the NoC readers as well as event...

Page 33: ...their booking permissions with them on their credentials Depending on the application booking permissions can be written onto a credential at a central location or can be transferred to a credential b...

Page 34: ...ty card if the original facility card gets lost It includes the object code for example The new facility card must be created by the supplier Door initialization card This card is used to transfer all...

Page 35: ...t the internal diagnostics memory NFC Card only for LEGIC You require the NFC card in connection with the PegaSys Mobile software If connections cannot be established with LEGIC devices hold the provi...

Page 36: ...data to and from credentials and cards for administration of the NetworkOnCard components Connect the read write unit to the computer Place the respective credential or card on the read write unit Tr...

Page 37: ...from 2 1 GREEN Booking memory entry Valid booking performed at a single door or at a door group Signaling Invalid booking RED RED RED Booking memory entry Card blocked invalid access authorization exp...

Page 38: ...utomatically toggle to permanently open mode at a specific time on defined days of the week and to toggle back to the standard mode at another time You can also configure the NetworkOnCard in such a w...

Page 39: ...56 4 52 2 74 256 8 60 2 82 256 16 76 2 98 512 2 80 2 102 512 4 84 2 106 512 8 92 2 114 512 16 108 3 130 768 2 112 3 134 768 4 116 3 138 768 8 124 3 146 768 16 140 3 162 1024 2 144 3 166 1024 4 148 4 1...

Page 40: ...single door or at a door group Invalid Booking The credential was read however the access booking is not correct RED RED RED Booking memory entry Card blocked invalid access authorization expired cre...

Page 41: ...memory entry No entry 4 RED Meaning Invalid time Remedy Create time initialization card and hold it to the NetworkOnCard component 5 RED Meaning The NetworkOnCard component has not been initialized Re...

Page 42: ......

Page 43: ...s control system Door leaf The moving part of the door element Door Leaf Open Positions of the door leaf in which neither latch nor bolt can interlock with the assigned openings of the locking plate o...

Page 44: ...on with authorization to activate the permanently open mode leaves the room the NetworkOnCard device toggles back to the not released mode Now the door can only be opened by means of a positive bookin...

Page 45: ...35 36 door leaf 35 36 drilling template 9 E emergency escape route 1 environment exposed to explosion hazards 2 escape door 1 escape route 1 ESD electrostatic discharge 2 F facility card 26 fire prot...