1.2  Safety instructions

Be sure to observe the following instructions: 

•  Make sure that the box is very well ventilated, as the output drivers can become up to 

100 °C hot at full load. 

•  Avoid touching cables and connectors etc. inside the PC with the card.

•  Never expose the device to direct sunlight during operation.

•  Never operate the device near heat sources.

•  Protect the device from moisture, dust, liquids and vapours.

•  Do not use the device in damp rooms and under no circumstances in potentially explosive 

areas.

•  Repairs may only be carried out by trained, authorised personnel.

•  When commissioning the instrument, please observe the installation regulations and all 

relevant standards (including VDE standards), especially when operating with voltages 
higher than 42 V. 

•  We recommend to always connect unused inputs to the corresponding reference ground to 

avoid crosstalk between the input channels.

•  Always disconnect your field wiring from the voltage source before you make or break cable 

connections to the card.

•  Make sure that no static discharge can occur through the device when handling the card. 

Follow standard ESD protection measures.

•  Never connect the devices to live parts, especially not to mains voltage.

•  Precautions to avoid unpredictable misuse must be taken by the user.

ALLNET® GmbH Computersysteme is not liable for improper use and resulting damage.

Summary of Contents for ADQ-51

Page 1: ...Manual Beta Rev 1 0 EN ADQ 51 USB Box with 8 isolated digital inputs and 8 isolated digital outputs ADQ 51...

Page 2: ...Mail support alldaq com Phone 49 0 89 894 222 74 Fax 49 0 89 894 222 33 Internet www alldaq com support Copyright 2020 ALLNET GmbH Computersysteme All rights reserved All information contained in thi...

Page 3: ...the box 9 2 2 Software installation 10 2 2 1 Installation on Windows 10 2 2 2 Installation on Linux 10 2 3 Testing program 10 3 Function groups 11 3 1 Block diagram 11 3 2 LED display status 11 3 3 Is...

Page 4: ...7 4 2 Pin assignments 20 4 2 1 ADQ 51 20 4 2 1 1 18 pin type Phoenix contact 20 4 3 Manufacturer and support 21 4 4 Important notes 21 4 4 1 Packaging ordinance 21 4 4 2 Recycling advice and RoHS conf...

Page 5: ...g on the packaging indicate that something has been damaged during trans port Can traces of use be seen on the device Under no circumstances may you put the device into operation if it is damaged In c...

Page 6: ...uthorised personnel When commissioning the instrument please observe the installation regulations and all relevant standards including VDE standards especially when operating with voltages higher than...

Page 7: ...ing a digital filter for each input port The ADQ 51 has 8 bit isolated digital inputs These isolated inputs have a Schmitt trigger cha racteristic according to IEC 61131 2 Type 1 and are designed for...

Page 8: ...epage you will find drivers for Windows Vista SP2 and higher 32 and 64 bit as well as a function library API with code examples for high level language program ming Please note the notes in the corres...

Page 9: ...he installation of additional hardware components before installing the box The box should be handled with care to ensure that the device is not damaged by electrostatic discharge ESD mechanical stres...

Page 10: ...info area of the taskbar usually at the bottom right or in the Windows start menu The ALLDAQ Manager gives you access to the Software Developer Kit SDK various utility programs and help files 2 2 2 I...

Page 11: ...per channel Isolated up to 500 VAC Digital 8 bit output port 8 bit Input port 8 bit digital output 8 bit digital input Control logic USB2 0 controller USB2 0 Fullspeed RDY PWR ACT ERR Fig 2 Block diag...

Page 12: ...lues 10ms N 1248 3 2ms N 400 1 0ms N 125 10 s Bypass The scan frequency is 100kHz typ 0 1 2 N 1 N 2 N 3 Scan frequency Input DI_x Filter outlet Filter status Signal is 1 Signal is 0 Filter time Signal...

Page 13: ...ut ports DI_x can be programmed independently of each other The port direction is determined by the hardware One digital filter can be programmed per port 10 ms 3 2 ms 1 ms 10 s bypass 3 3 3 1 Read in...

Page 14: ...f outputs can be connected in parallel A ground reference to the external output circuitry must be established via GND The digital input and output parts use a common GND The output stage offers a com...

Page 15: ...oltage source must be connected to the UEXT pins which can provide sufficient power At full load this is up to 5 6 A for the ADQ 51 Attention The Phoenix DFMC 1 5 9 ST 3 5 LR 1790551 connector may hea...

Page 16: ...1 Single value output In this operating mode you can output one digital value each in the respective port width Note An output port can also be read back Please observe the procedure as described in t...

Page 17: ...low Uext supply Shutdown min 8 0V Startup max 9 6V Hysteresis typ 1V with the Uext missing Switch on threshold min 12 1 V switch off threshold max 13 9 V Input level UEXT 24V L H 15 V H L 11 V Hystere...

Page 18: ...protection UEXT min 47VDC Dissipated energy with inductive load Per channel max 1 Joule Resistance at active output IO 0 5A TA 25 C typ 150m max 200m Leakage current with inactive channel typ 5 A max...

Page 19: ...tus LEDs Power USB Ready Act Error Operating temperature Operation 0 70 C Storage 40 100 C Humidity Operation 20 55 non condensing Storage 5 90 non condensing Dimensions without plug USB2 0 90x63x33mm...

Page 20: ...ND GND isolated from PC ground GND_PC 2 UEXT 16 35 VDC typ 24 VDC for control technology 3 DO_6 Digital output 4 DO_7 Digital output 5 DO_4 Digital output 6 DO_5 Digital output 7 DO_2 Digital output 8...

Page 21: ...ycled according to 4 sentence 1 of the Packaging ordinance If you as a customer have problems disposing of the packaging and shipping materials please write an e mail to info allnet de 4 4 2 Recycling...

Page 22: ...al defects free of charge You will find the warranty conditions valid for your country on the homepage of your distributor If you have any questions or problems concerning the application you can reac...

Page 23: ...Annex 23 Manual ADQ 51 Rev 1 0 Annex...

Page 24: ...ALLNET GmbH Computersysteme Division ALLDAQ Maistrasse 2 D 82110 Germering E Mail support alldaq com Phone 49 0 89 894 222 74 Fax 49 0 89 894 222 33 Internet www alldaq com...

Reviews: