PARAMETER SETTING MODE
3.
Press the push-button rotary knob.
The unit will go back to menu mode.
DTMF MONITOR
Set whether or not to output tones and tone calls output using the
automatic dialer from the speaker of the unit.
1.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to display the menu number "23".
The current setting will appear on the display.
The default setting is [DTM.ON].
2.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to change the setting.
The options are as follows.
▼
ON:
Outputs tones and tone calls output using the automatic dialer
from the speaker of the unit.
▼
OFF:
Does not output tones and tone calls output using the automatic
dialer from the speaker of the unit.
3.
Press the push-button rotary knob.
The unit will go back to menu mode.
Scan Type
This is to select the scan resume condition. TIMER setting allows the
radio to resume scanning after 5 seconds, regardless of the signal
receiving status. BUSY setting resumes scanning when the received
signal is gone. The scan mode is explained later.
1.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to display the menu number "24".
The current setting will appear on the display.
The default setting is [SCAN.TMR].
2.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to change the setting.
The options are as follows.
▼
TMR: Activates the timer scan.
▼
BSY: Activates the busy scan.
3.
Press the push-button rotary knob.
The unit will go back to menu mode.
SCANNING STOP TIME -TMR
From "Switching the Scanning Type", select "Timer scan" to set the
duration of time before switching to the next channel when receiving a
signal.
1.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to display the menu number "25".
The current setting will appear on the display.
The default setting is [ST-T.5] (5sec).
2.
Rotate the push-button rotary knob or press the [UP]/[DOWN] keys
on the microphone to change the setting.
The options are as follows.
▼
3 (sec) to 10 (sec) (8 steps in 1 second increments)
3.
Press the push-button rotary knob.
The unit will go back to menu mode.