17
Press and hold
11
key until activating the function menu. Rotate
the dial or use
[UP/DOWN]
keys to select the menu 05 BEEP and
press the dial.
Rotate the dial or use
21
[UP/DOWN]
keys to
select the value from
ON:
Turn on Beep function.
OFF:
Turn off Beep function.
OFF setting turns off the beep sounds.
Press [PTT] to set and exit or press the dial to set and continue.
31
MENU 05: BEEP SOUND
6
Parameter Setting Mode (SET MODE)
Press and hold
11
key until activating the function menu. Rotate
the dial or use
[UP/DOWN]
keys to select
the menu 06 CLKSFT and press the dial.
Rotate the dial or use
21
[UP/DOWN]
keys to
select the value from
ON:
Change CPU clock.
OFF:
CPU clock frequency remain unchanged.
When you hear a noise-interference always on a certain same
31
channel even without connecting to the antenna, try setting it to ON
parameter. If the noise is CPU clock related, it may be eliminated.
This feature is not a noise-blanker.
Press [PTT] to set and exit or press the dial to set and continue.
41
Press and hold
11
key until activating the function menu. Rotate
the dial or use
[UP/DOWN]
keys to select the menu 07 2T ENC and
press the dial.
Rotate the dial or use
21
[UP/DOWN]
keys to
select the value from 0-23, total 24 groups.
If the 2TONE encode are programmed
with name, the LCD will display the
correspondent name.
Press [PTT] to set and exit or press the dial to set and continue.
31
Press and hold
11
key until activating the function menu. Rotate
the dial or use
[UP/DOWN]
keys to select
the menu 08 5T ENC and press the dial.
Rotate the dial or use
21
[UP/DOWN]
keys
to select the value from 0-99, total 100
groups.
If the 5TONE encode are programmed with name, the LCD will
display the correspondent name.
Press [PTT] to set and exit or press the dial to set and continue.
31
MENU 06: CPU CLOCk FREQUENCY SETTING
MENU 07: 2TONE ENCODE SELECT
MENU 08: 5TONE ENCODE SELECT
After choose the 2TONE encode group. Press [PTT] will transmit
selected code.
NOTE
After choose the 5TONE encode group. Press [PTT] will transmit
selected code.
NOTE
OFF:
Turn off VFO band lockout function.
The scanning or frequency setting through the dial or numerical keys
31
become available only within the current VFO frequency band.
Press [PTT] to set and exit or press the dial to set and continue.
41