C613-50163-01 Rev C
Command Reference for GS970M Series
1377
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
E
THERNET
P
ROTECTION
S
WITCHED
R
ING
(EPSR
ING
™) C
OMMANDS
EPSR
MODE
MASTER
CONTROLVLAN
PRIMARY
PORT
epsr mode master controlvlan primary port
Overview
NOTE
:
This command will only run on switches that are capable of running as an EPSR
master node. However, even if your switch cannot function as an EPSR master node,
you still need to configure this command on whatever switch is the master within your
EPSR network.
This command creates a master EPSR instance. Your switch is unable to run this
command because it cannot function as an EPSR master node. To include these
switches in an EPSR ring you will need to use an alternative Allied Telesis switch,
such as an x610 Series switch, as the master node. For more information on this
command, refer to the manual of your master EPSR node’s switch.
NOTE
:
The software allows you to configure more than two ports or static channel
groups to the control VLAN within a single switch. However, we advise against this
because in certain situations it can produce unpredictable results.