3

www.observint.com

© 2018 Observint Technologies. All rights reserved.

12 Vdc Power Connector

Alarm IN / OUT terminals

Audio  

terminals

Ethernet connector

f.  Connect the 12 Vdc power cables to the drop cable power connector, if needed. Observe the 

polarity of the connector as shown in the picture above. 

10.  Attach the camera base assembly to the adapter plate using the three (3) machine screws provided. 

Align the base assembly so that the locator pins on the adapter plate slip into the with the locator 
holes on the base and that the camera is pointing at your surveillance target. 

11.  Apply power to the camera through the 12 Vdc extension cable or through the Ethernet cable using 

PoE. 

Step 2.  Install the Alibi Config Tool software

NOTE: 

If the camera LAN extension cable is attached to a Network Video Recorder (NVR) internal switch, 

skip this step. 
The Alibi Config Tool is a PC-based network utility for discovery of Alibi compatible devices. It provides 
an easy way to activate devices, configure camera and recorder network configuration settings, and set 
device passwords. It can be installed on a Microsoft® Windows® operating system that has direct access 
to the network where your Alibi devices are installed. You can download the Alibi Configuration Tool from 

Supercircuits.com

 or 

AlibiSecurity.com/Resources

1.  Download the Alibi Config Tool from the 

Supercircuits.com

 or 

AlibiSecurity.com/Resources 

website. At the time when this document was published, the file is named: 

alibi-config-tool.zip

 and 

is about 80MB. 

2.  Un-zip the file on a computer with Microsoft Windows (Windows 7 or newer) that is connected to the 

LAN where your Alibi camera is connected. 

3.  Run the file contained in the zip file: 

Alibi Config Tool.exe

. Follow the on-screen instructions to 

install the file. 

4.  Open the Alibi Config Tool application. When the application opens, it automatically “discovers” and 

lists all Alibi compatible devices on the LAN. See below.

Notice: In the screen above, the tool discovered devices with IP addresses of 192.168.0.xxx and 
192.168.3.xxx. It will also list other Alibi compatible devices on the LAN, and devices with the 
address 192.168.1.64 (an inactive Alibi device). 

Step 3.  Activate Inactive Alibi device

NOTE: 

If the camera LAN extension cable is attached to a Network Video Recorder (NVR), skip this step. 

Refer to the documentation available for your NVR firmware for the procedure to activate the camera, if 
necessary. 

When an Alibi device is first installed, or reset to its factory configuration, it must be “Activated” before it 
can be used. In the Alibi Configuration Tool, “Inactive” devices have a 

Security

 status of 

Inactive

, and 

an IPv4 address of 

192.168.1.64

. A device is “Activated” when a password is assigned to the 

admin

 

username of the device. 
In the example below, an ALI-NS1124VR camera is activated and configured for its network. The procedure 
is similar for all other Alibi network cameras currently available.
1.  Scan through the list of devices the Alibi Config Tool discovered for the Inactive device you want to 

activate (see below). Click on the device in the list to highlight it, and then click the select box to check 
it. See below. 

Activate

2.  Click the 

Activate

 button. In the Activate window, you will create a password for the 

admin

 

(administrator) username. 

a.  In the Activate window, enter an a password for 

admin

 in the 

New Password

 field. Include a 

combination of uppercase, lowercase alphabetic characters and numbers to create a “Strong” 
password. The rating is shown beneath the field. See above. 

b.  Enter the 

admin

 password again in the 

Confirm

 field, and then click 

Activate

. In the screen 

below, notice that the device Security status shows “Active”. 

Record your admin password 

for reference later.

 

CAUTION

If you lose your 

admin

 (administrator) password, you cannot configure the device or restore 

it to its factory settings. To reset your password, 

call

 your support organization for specific 

instructions. 

Notice that although the device is now activated, it retained the default IP address. 

Step 4.  Modify Network Parameters

NOTE:

 If the camera LAN extension cable is attached to a Network Video Recorder (NVR), skip this step. 

The camera will receive network configuration settings from the NVR. Refer to the documentation available 
for your NVR firmware for more information. 

Summary of Contents for ALI-NS1124VR

Page 1: ...is document ALI NS1124VR 4 0 Megapixel IR Mini Dome IP Camera Quick Installation Guide The ALIBI ALI NS1124VR dome camera includes 4 0 megapixel video performance in a small form factor network camera...

Page 2: ...nge 12 Vdc 25 CAUTION Do not apply power to the camera at this time Before applying power to the camera ensure that the polarity is correct An incorrect connection may cause a malfunction and can dama...

Page 3: ...168 3 xxx It will also list other Alibi compatible devices on the LAN and devices with the address 192 168 1 64 an inactive Alibi device Step 3 Activate Inactive Alibi device NOTE If the camera LAN e...

Page 4: ...work parameters see below Step 5 Login to the camera NOTE If the camera LAN extension cable is attached to a Network Video Recorder NVR skip this step Microsoft IE is used to access your camera remote...

Page 5: ...the outer camera cover The outer cover unsnaps from the dome cover 2 Use a 2 Phillips screwdriver to unscrew the four captive screws that secure the dome cover to the base assembly and then separate i...

Page 6: ...ministrative credentials 2 Click the Setup tab and then click the Image link in the left frame 3 Adjust the Brightness Contrast Saturation and Sharpness of the image Each parameter can be set to a lev...

Page 7: ...100M Ethernet interface Alarm 1 Input Alarm in 1 Output Alarm out terminal block On board storage Built in Micro SD SDHC SDXC slot up to 128 GB Reset Button Yes Audio Environment Noise Filtering Supp...

Page 8: ...f 20 VA which is installed 77 feet 22 m from the transformer the minimum wire gauge required is 1 0000 mm 18 gauge Power VA Wire size mm gauge 0 800 20 1 000 18 1 250 16 2 000 12 10 97 28 153 44 234 6...