Check
Notes
DELIVERY
SUPPLIED COMPLETE?
CHECK THERE HAS NOT BEEN ANY TRANSIT DAMAGE
POSITION
LEVEL AND STABLE?
ON SOUND, WATERPROOF, SELF-DRAINING FLOOR
WATER
ISOLATOR VALVE FITTED?
ACCESSIBLE, ALL FITTINGS SOUND, AND NO LEAKS
TEMPERATURE CORRECT?
HOT WATER INLET 65˚C
PRESSURE CORRECT (200 – 350 kPa)?
LIMITER FITTED IF ABOVE RANGE
FLOW RATE CORRECT (
≥
20L PER MIN)?
FLOW RATE AT OR ABOVE MINIMUM RANGE
QUALITY WITHIN REQUIREMENTS?
FILTER OR SOFTENER IN PLACE IF OUTSIDE REQUIREMENTS
POWER
ISOLATING SWITCH?
FITTED, FUNCTIONAL AND ACCESSIBLE
CORRECT SUPPLY (1P/15A 240V 50Hz)?
VOLTAGE, CURRENT, CIRCUIT BREAKER ALL CORRECT
WASTE
40MM CONNECTION (1.5” BSP)?
HARD PLUMBED, NO LEAKS
SUITABLE AIR GAP?
REFER INSTALLATION INSTRUCTIONS - WASTE
CHEMICALS
CHEMICAL NAME
CONTAINER
NO LEAKS
PRIMED
CALIBRATED
DETERGENT
RINSE FLUID
MACHINE OPERATION
MACHINE RUNNING CORRECTLY?
MULTIPLE CYCLES RUN, NO ISSUES
CHEMICAL DOSAGE CORRECT?
CORRECTLY FLOWING INTO MACHINE, NO FOAMING
ALL OPERATIONS CORRECT?
FILL LEVEL CORRECT, NO DRAINAGE ISSUES
OPERATOR TRAINING
ENSURE THAT THE CUSTOMER HAS BEEN GIVEN THE OPERATION MANUAL AND WALL CHART, AND IS AWARE OF THE
IMPORTANCE OF BOTH USING AND CLEANING THE MACHINE CORRECTLY.
START UP
PRE-RINSE AND RACKING
BETTER TO RINSE PLATES THAN REMOVE WASTE FROM MACHINE
MACHINE USE AND CYCLE SELECTION
USE LONG CYCLE WHERE POSSIBLE
DRAINING THE MACHINE
DRAIN THE MACHINE DAILY
SHUT-DOWN AND DAILY CLEANING
CHECK WASH ELEMENTS HAVE COOLED BEFORE CLEANING
WEEKLY MAINTENANCE
FULL MACHINE CLEAN INCLUDING WASH/RINSE ARMS
PLANNED SERVICNG
IMPORTANCE OF HAVING MACHINE SERVICED REGULARLY
7/31/2019
Starline XP-3 Operator Manual
7
Installation Checklist