background image

 

GAS SUPPLY INSTALLATIONS: 
 

Because of the 

Alfresco

™  Pizza Oven’s unique design, it is possible to install the gas supply (NG 

or LP) from a place below the unti in addition to the standard back supply location. 
 
The oven is constructed with an opening at the bottom heat shield to facilitate connections from below. 
(See figure # 8
 

Standard connections through the back panel can be con-
verted to bottom connections as follows: 
 

• 

Removing the 3/8” (LP) or 1/2” (NG) Brass compression 
fitting on the back, 

• 

Rotating down the 90° 1/2” elbow immediately behind  
the back panel, 

• 

Re-installing the appropriate size compression fitting for 
a flexible hose connections, or… 

• 

Hard-piping the oven with 1/2” NPT piping. 

 
 

 
 
 
 
 
 
 
 

 

 
 
 

When designing a built in enclosure with gas supplies connected from the bottom of the unit, a shut-off 
valve with unrestricted access is required. 
 
Always shut off the gas supply when the unit is not in use to ensure safety. 
 
 
 
For additional ALF-PZA-BIA product dimensions which might aid in the construction of your built-in en-
closure, please refer to the ALF-PZA-

BIA Specification Sheet found in our website;

 

 

www.alfrescogrills.com 

 
 

Figure # 8

 

(2) 90° 1/2” ELBOWS 

CONVERTIBLE 
PRESSURE 
REGULATOR 

ELECTRICAL 
CORD 

3/8” OR 1/2” 
COMPRESSION 
FITTING 

TURN DOWN 
ELBOW 

CONNECTION 
OPENING 

BOTTOM HEAT 
SHIELD 

Summary of Contents for ALF-PZA-BIA

Page 1: ......

Page 2: ...raight up Do not remove the top radiant stone it s designed to stay there See Figure 1 Install the BIA Kit Hood by laying it on top and sliding forward until all the screw holes located in it s sides and back line up correctly with the holes in the body of the ALF PZA See Figure 2 Fasten all 9 self tapping screws to permanently fix the BIA Hood to the body of the ALF PZA Unit Once the BIA Hood is ...

Page 3: ...ng the pizza oven into a non combustible structure it is critical to have access to the bottom of the unit This will be the only means of service and maintenance as the oven will no longer be removable Alfresco recommends installing an AB 30 double sided door for service storage gas supply and electrical power access The Pizza Oven must rest on two 2 ledges to give it proper sup port and must have...

Page 4: ...ofing is strongly recommended on the top section of the built in enclosure as to have a complete weather tight assembly around all areas including but not limited to the vent flue design See Figure 7 It is highly recommended to install access doors below the ALF PZA unit when designing the built in construction such as Alfresco s AB Doors The access is required for piping LP or NG shut off valves ...

Page 5: ...nd the back panel Re installing the appropriate size compression fitting for a flexible hose connections or Hard piping the oven with 1 2 NPT piping When designing a built in enclosure with gas supplies connected from the bottom of the unit a shut off valve with unrestricted access is required Always shut off the gas supply when the unit is not in use to ensure safety For additional ALF PZA BIA pr...

Page 6: ...6 ...