background image

150 TURBO / 150 

Ultima modifica/ Last Update: 18/03/2008   Rev0                                                                                                                       pagina 14 di 15 

 

 

EXPLANATION 

 

 

Tester or digital millimetre. “OL” means Open Loop.  

P

IC

T

U

R

E

 6

 

Summary of Contents for 150 TP

Page 1: ...Vaši bezpečnost je nutné posečkat se sundáním krytu ze stroje po odpojení ze sítě po dobu minimálně 5 minut kdy klesne napětí na kondenzátorech na hodnotu pod 36 V NOTE Only trained personnel are permitted to work inside the machine BEFORE OPENING THE MACHINE CUT OFF ITS ELECTRICAL POWER BY REMOVING THE PLUG FROM THE MAINS SUPPLY SOCKET Every six months open the machine and clean it inside using c...

Page 2: ...MG062 2 SERVISNÍ MANUÁL SERVICE MANUAL ALFIN 150 TP page 2 ALFA IN a s SERVISNÍ TECHNICKÁ DOKUMENTACE ...

Page 3: ...MG062 2 SERVISNÍ MANUÁL SERVICE MANUAL ALFIN 150 TP page 3 ALFA IN a s SERVISNÍ TECHNICKÁ DOKUMENTACE 3 NÁHRADNÍ DÍLY SPARE PARTS ...

Page 4: ...Panel přední Alfin150M FRONT PLASTIC PANEL 11 014 002 0011 Knoflík ALFIN modrý 1980 M KNOB 12 012 001 0006 Kryt spodní Alfin150 LOWER COVER 13 040 003 1080 Termostat Alfin140ET TERMAL SWITCH 14 045 006 0002 Propoj kladného pólu Alfin140E COPPER BRACKET 15 015 001 0003 Chladič L 75 Alfin140ET HEAT SINK L 75mm 16 032 002 0255 Usměrňovač výstupní Alfin DIODE 17 050 001 0043 PCB 150TP DOUBLER OVERCUT ...

Page 5: ...e kontaktů v konektoru teplotní čidlo žluté dráty pozice 2 5 drát pro snímání výstupního napětí červený pozice 3 dráty bočníku pozice 1 4 Zkontrolujte spojení kontaktů tepelné ochrany pomocí testeru diod teplota chladiče nesmí být vyšší než 40 C Zkontrolujte spojení mezi objímkou a červeným drátem Zkontrolujte průchodnost mezi objímkou a vodiči bočníku ...

Page 6: ...trolu můstku změřte tento podle následující tabulky testerem diod Červený vodič Černý vodič Naměřená hodnota F D OL D F 0 450 D F OL F D 0 450 Pro kontrolu tranzistorů změřte tyto podle následující tabulky testerem diod červený černý hodnota S G 0 28 G S 0 6 Hodnoty jsou orientační Naměříte li zkrat nebo rozpojený obvod OL je nutné PCB vyměnit ...

Page 7: ...ou PCB Toto zařízení slouží k ochraně PCB před vstupním přepětím Při přepětí exploduje a zkratuje vstup Je li rozsah zkratu velmi vysoký obvod se přeruší Pro kontrolu tranzistor změřte podle následující tabulky testerem diod červený černý hodnota G D 0 5 D S OL G S 0 6 Hodnoty jsou orientační Naměříte li zkrat nebo rozpojený obvod OL je nutné PCB vyměnit ...

Page 8: ...MG062 2 SERVISNÍ MANUÁL SERVICE MANUAL ALFIN 150 TP page 8 ALFA IN a s SERVISNÍ TECHNICKÁ DOKUMENTACE Digitální multimetr OL označuje přerušený obvod ...

Page 9: ...d the machine does not go on Damaged power supply cable with short circuited wires Inverter is damaged Switch off the machine and disconnect the plug Make sure that there are no short cir cuits between the poles of the plug caused by a damaged power supply cable Switch off the machine disconnect the plug and check varistors picture 4 inverter picture 3 Input bridge rectifier picture 2 switching po...

Page 10: ...rmally closed If one of the protection devices is always opened it is defective it must be accordingly replaced If it is closed make sure the two terminals are well inserted in the connector picture 1 Power board feed problems it must be accordingly replaced The output voltage in MMA is zero Switch the machine off and disconnect the plug Check for a short circuit at the DINSE plug with a diode tes...

Page 11: ...urrent does not re quire greater power than the one supplied by the line Decrease the welding current The machine always welds at maximum cur rent The Front Panel is damaged The Power Board is damaged The shunt wires are damaged or not cor rectly inserted in the 6 pin connector The doubler board is damaged Switch off the machine and disconnect the plug The Front Panel must be replaced The Power Bo...

Page 12: ...e diode tester with the heat sink tool temperature less than 40 C Check the continuity between socket and the red wire so cket and the shunt Input bridge rectifier on the power board To check the Input bridge rectifier carry out the following measurements with a diode tester Should there be a short circuit on one of these measurements the input bridge rectifier must be replaced Shunt Output voltag...

Page 13: ...the board from input overvoltage When there is overvoltage it explodes causing a short circuit most of the times If the extent of the short circuit is very high they become an open circuit To check the mosfet of the switching power supply unit carry the following measurements with a diode tester Should there be a short circuit on one of these measurements or an OL instead of a numeric value the po...

Page 14: ...150 TURBO 150 Ultima modifica Last Update 18 03 2008 Rev0 pagina 14 di 15 EXPLANATION Tester or digital millimetre OL means Open Loop PICTURE 6 ...

Page 15: ...MG062 2 SERVISNÍ MANUÁL SERVICE MANUAL ALFIN 150 TP Vypracoval Worked out DJ 15 4 2010 Přezkoumal Inspected DJ 15 4 2010 Schválil Approved VS 15 4 2010 ...

Reviews: