150 T / 150 W 

Ultima modifica/ Last Modify: 18/03/2008  Rev0                                                                                                 pagina 14 di 17 

 

 

EXPLANATION 

 

 

Input bridge rectifier . 
 
To check the Input bridge rectifier , carry out the following 
measurements with a diode tester: 

 
 
 
 
 
 
 
 
 
 

Should there be a short circuit on one of these measurements, 
the input bridge rectifier must be replaced. 

 

 

To check the inverter, carry out the following measurements 
with a diode tester: 

 
 
 
 
 
 
 
 
 
 
 
 
 

Should there be a short-circuit on one of these measurements 
or an “OL” instead of a numeric value, the power board must 
be replaced. 

 

 

The varistor is a blue disc near the ground wire of the power 
board.  This  device  is  for  protecting  the  board  from  input 
overvoltage. When there is overvoltage it “explodes” causing a 
short circuit most of the times. If the extent of the short circuit 
is very high they become an open circuit.    

Faston 

Probe 

Faston 

Probe 

Measure

 

F+ 

red 

black 

“OL” 

F

 

 

red 

black 

>.450 

F+ 

black 

red 

“OL” 

F- 

black 

red 

>.450 

P

IC

T

U

R

E

 3

 

F+ 

F- 

G D S 

G

 D

 S

 

G

 D

  

G

 D

 S

 

P

IC

T

U

R

E

 4

 

Red Probe 

Black Probe 

Measure

 

0.28 

0.6 

P

IC

T

U

R

E

 5

 

Varistor 

Summary of Contents for 150 TIG HF

Page 1: ...ezpe nost je nutn pose kat se sund n m krytu ze stroje po odpojen ze s t po dobu minim ln 5 minut kdy klesne nap t na kondenz torech na hodnotu pod 36 V NOTE Only trained personnel are permitted to wo...

Page 2: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF page 2 ALFA IN a s SERVISN TECHNICK DOKUMENTACE...

Page 3: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF page 3 ALFA IN a s SERVISN TECHNICK DOKUMENTACE 3 N HRADN D LY SPARE PARTS...

Page 4: ...TOPE DIODE 1 15 040 001 0002 chr ni hl vyp TWO POLE SWITCH 1 16 040 003 1080 termostat THERMAL CUT OUT 1 17 042 003 0001 trafo PLANAR TRANSFORMER 1 18 045 000 0001 v vodka 1 CABLE GRIP 1 1 19 045 000...

Page 5: ...E MANUAL ALFIN 150 TIG HF page 5 ALFA IN a s SERVISN TECHNICK DOKUMENTACE 35 021 004 3360 konektor ovl ho ku TORCH CONNECTOR 1 36 046 004 0003 izol tor pod HF PCB HF BOARD INSULATION 1 4 KONTROLA SILO...

Page 6: ...ce 3 dr ty bo n ku pozice 1 4 Zkontrolujte spojen kontakt tepeln ochrany pomoc testeru diod teplota chladi e nesm b t vy ne 40 C Zkontrolujte spojen mezi obj mkou a erven m dr tem Zkontrolujte pr chod...

Page 7: ...sleduj c tabulky testerem diod erven ern hodnota S G 0 28 G S 0 6 Hodnoty jsou orienta n Nam te li zkrat nebo rozpojen obvod OL je nutn PCB vym nit Varistor je bl zko vstupu nap jec ho nap t na silov...

Page 8: ...a s SERVISN TECHNICK DOKUMENTACE Pro kontrolu tranzistor zm te podle n sleduj c tabulky testerem diod erven ern hodnota G D 0 5 D S OL G S 0 6 Hodnoty jsou orienta n Nam te li zkrat nebo rozpojen obvo...

Page 9: ...switch is activated and the machine does not go on Damaged power supply cable with short circuited wires Inverter is damaged Switch off the machine and disconnect the plug Make sure that there are no...

Page 10: ...Switch off the machine and disconnect the plug Make sure that the wiring contact is cor rectly inserted in the connector Check for continuity between the out put outlets and that the 6 path connector...

Page 11: ...e correctly inserted picture 8 The front panel must be replaced The HF board could be damaged in that case it must be replaced Should the operations carried out not have a positive outcome replace the...

Page 12: ...uity of contact of the thermal protection de vice with the diode tester with the heat sink tool temperature less than 40 C Check the continuity between socket and the shunt socket and the output volta...

Page 13: ...rcuit on one of these measurements or an OL instead of a numeric value the power board must be replaced The varistor is a blue disc near the ground wire of the power board This device is for protectin...

Page 14: ...er supply unit carry the following measurements with a diode tester Should there be a short circuit on one of these measurements or an OL instead of a numeric value the power board must be replaced Te...

Page 15: ...he Front Panel and the HF board is whole and well inserted for HF transformer and Solenoid Valve problem Check that the ampenol wiring are intact and well inserted In order to reset the parameters swi...

Page 16: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF Vypracoval Worked out DJ 15 4 2010 P ezkoumal Inspected DJ 15 4 2010 Schv lil Approved VS 15 4 2010...

Reviews: