PROBLEM 

CASE 

SOLUTION

 

The machine does not 
switch on. 

 

Electrical power does not reach the ma-
chine. 

 
 
 

 

Voltage reaches the machine switch but 
there is no voltage after the contacts.  

 
 

 

There is voltage after the disconnecting 
switch but the machine does not go on.  

!

Make sure the line switches are closed, the 
protection devices (fuses) have not been 
enabled and that the power supply cable is 
intact. 

!

Switch the machine off and disconnect the 
plug. Make sure that when the switch is 
closed, there is continuity between the 
contact input and output and that the varis-
tor is not broken (picture 5). If it’s dama-
ged, the Power Board must be replaced. 

!

Switch the machine off and disconnect the 
plug. Check the mosfet of the switching 
power supply unit on the power board 
(picture 6). If it’s damaged, the Power 
Board must be replaced. 

The protection devices 
of the line set off when 
the switch is activated 
and the machine does 
not go on. 

 

Damaged power supply cable with short-
circuited wires.  

 
 

 

Inverter is damaged. 

!

Switch off the machine and disconnect the 
plug. Make sure that there are no short cir-
cuits between the poles of the plug caused 
by a damaged power supply cable.  

!

Switch  off  the  machine,  disconnect  the 
plug and check: 
-   varistors (picture 5); 
-   l’inverter (picture 4); 
-   Input bridge rectifier (picture 3) 

 

switching power supply unit (picture 6). 

If  one  of  these  components  is  damaged 
replace the power board. 

The front panel does 
not switch on. 

 

The fan works but the front panel does 
not go on. 

 
 
 
 
 
 

 

Both the fan and the front panel do not 
work. 

!

Switch off the machine and disconnect the 
plug. Make sure the flat cable that con-
nects the front panel to the power board is 
inserted correctly. If correctly inserted, re-
place the front panel. If the front panel 
does not go on, one of the switching power 
supply unit outputs is broken. Therefore 
the power board must be replaced. 

!

Switch off the machine, disconnect the 
plug and check the mosfet of the switching 
power supply unit (picture 6). 

 !"#$%&'(

)*+,-*( ./--0123( ,45( /20( 6,-7( ,2( 58*( 9/.812*(

9/7*( :4-*( 15( 1:( ,++( /2;( 58*( <=43( 8/:( >**2( ;1:?

.,22*.5*;@(

'(

Summary of Contents for 150 TIG HF

Page 1: ...ezpe nost je nutn pose kat se sund n m krytu ze stroje po odpojen ze s t po dobu minim ln 5 minut kdy klesne nap t na kondenz torech na hodnotu pod 36 V NOTE Only trained personnel are permitted to wo...

Page 2: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF page 2 ALFA IN a s SERVISN TECHNICK DOKUMENTACE...

Page 3: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF page 3 ALFA IN a s SERVISN TECHNICK DOKUMENTACE 3 N HRADN D LY SPARE PARTS...

Page 4: ...TOPE DIODE 1 15 040 001 0002 chr ni hl vyp TWO POLE SWITCH 1 16 040 003 1080 termostat THERMAL CUT OUT 1 17 042 003 0001 trafo PLANAR TRANSFORMER 1 18 045 000 0001 v vodka 1 CABLE GRIP 1 1 19 045 000...

Page 5: ...E MANUAL ALFIN 150 TIG HF page 5 ALFA IN a s SERVISN TECHNICK DOKUMENTACE 35 021 004 3360 konektor ovl ho ku TORCH CONNECTOR 1 36 046 004 0003 izol tor pod HF PCB HF BOARD INSULATION 1 4 KONTROLA SILO...

Page 6: ...ce 3 dr ty bo n ku pozice 1 4 Zkontrolujte spojen kontakt tepeln ochrany pomoc testeru diod teplota chladi e nesm b t vy ne 40 C Zkontrolujte spojen mezi obj mkou a erven m dr tem Zkontrolujte pr chod...

Page 7: ...sleduj c tabulky testerem diod erven ern hodnota S G 0 28 G S 0 6 Hodnoty jsou orienta n Nam te li zkrat nebo rozpojen obvod OL je nutn PCB vym nit Varistor je bl zko vstupu nap jec ho nap t na silov...

Page 8: ...a s SERVISN TECHNICK DOKUMENTACE Pro kontrolu tranzistor zm te podle n sleduj c tabulky testerem diod erven ern hodnota G D 0 5 D S OL G S 0 6 Hodnoty jsou orienta n Nam te li zkrat nebo rozpojen obvo...

Page 9: ...switch is activated and the machine does not go on Damaged power supply cable with short circuited wires Inverter is damaged Switch off the machine and disconnect the plug Make sure that there are no...

Page 10: ...Switch off the machine and disconnect the plug Make sure that the wiring contact is cor rectly inserted in the connector Check for continuity between the out put outlets and that the 6 path connector...

Page 11: ...e correctly inserted picture 8 The front panel must be replaced The HF board could be damaged in that case it must be replaced Should the operations carried out not have a positive outcome replace the...

Page 12: ...uity of contact of the thermal protection de vice with the diode tester with the heat sink tool temperature less than 40 C Check the continuity between socket and the shunt socket and the output volta...

Page 13: ...rcuit on one of these measurements or an OL instead of a numeric value the power board must be replaced The varistor is a blue disc near the ground wire of the power board This device is for protectin...

Page 14: ...er supply unit carry the following measurements with a diode tester Should there be a short circuit on one of these measurements or an OL instead of a numeric value the power board must be replaced Te...

Page 15: ...he Front Panel and the HF board is whole and well inserted for HF transformer and Solenoid Valve problem Check that the ampenol wiring are intact and well inserted In order to reset the parameters swi...

Page 16: ...MG014 2 SERVISN MANU L SERVICE MANUAL ALFIN 150 TIG HF Vypracoval Worked out DJ 15 4 2010 P ezkoumal Inspected DJ 15 4 2010 Schv lil Approved VS 15 4 2010...