31
Eve Double Pro-line | Version 1.0 | June 2020
ENGLISH
APPENDIX B: DEFAULT SELECTIONS FOR
OPTIONAL FACTORY SETTINGS
Measured value
Step size
Data type
Voltage L1L2 [V]
0.01 [V]
UNSIGNED32
Voltage L2L3 [V]
0.01 [V]
UNSIGNED32
Voltage L3L1 [V]
0.01 [V]
UNSIGNED32
Voltage L1N [V]
0.01 [V]
UNSIGNED32
Voltage L2N [V]
0.01 [V]
UNSIGNED32
Voltage L3N [V]
0.01 [V]
UNSIGNED32
Frequency [Hz]
0.001 [Hz]
UNSIGNED32
Current L1 [A]
0.001 [A]
UNSIGNED32
Current L2 [A]
0.001 [A]
UNSIGNED32
Current L3 [A]
0.001 [A]
UNSIGNED32
Current N [A]
0.001 [A]
UNSIGNED32
Active Power Sum [W]
0.1 [W]
SIGNED32
Reactive Power Sum [VAr]
0.1 [VAr]
SIGNED32
Apparent Power Sum [VA]
0.1 [VA]
UNSIGNED32
Cos(phi) Sum [ ]
0.001 [ ]
SIGNED32
Active Power L1 [W]
0.1 [W]
SIGNED32
Active Power L2 [W]
0.1 [W]
SIGNED32
Active Power L3 [W]
0.1 [W]
SIGNED32
Reactive Power L1 [VAr]
0.1 [VAr]
SIGNED32
Reactive Power L2 [VAr]
0.1 [VAr]
SIGNED32
Reactive Power L3 [VAr]
0.1 [VAr]
SIGNED32
Apparent Power L1 [VA]
0.1 [VA]
UNSIGNED32
Apparent Power L2 [VA]
0.1 [VA]
UNSIGNED32
Apparent Power L3 [VA]
0.1 [VA]
UNSIGNED32
Cos(phi) L1 [ ]
0.001 [ ]
SIGNED32
Cos(phi) L2 [ ]
0.001 [ ]
SIGNED32
Cos(phi) L3 [ ]
0.001 [ ]
SIGNED32
The table below provides an overview of values that can be read. Because the charging stations adjust to the currents per
phase (bold in the table), this is the minimal information necessary to operate the active load balancing.