11
Eve Double Pro-line | Version 1.0 | June 2020
ENGLISH
2.4 Eve Double Pro-line with single or double feeder cables
The international standard for conductive charging systems for electric vehicles is the IEC-61851-1. All charging
equipment should be installed according to the IEC-61851-1 standard.
Required on-site short-circuit protection:
For 2x3.7kW/11kW
Circuit breaker 40A type B, or 35A gG
fuses Load balancing optional
For 2x7.4kW/22kW
Circuit breaker 40A type B, or 35A gG
fuses Load balancing required
Eve 904461031 (1-phase)
Eve 904461021 (3-phase)
Overcurrent protection
Foutstroom-
beveiliging
Fault current
protection
Foutstroom-
beveiliging
Fault current
protection
Eve 904461032 (1-phase)
Eve 904461022 (3-phase)
Overcurrent protection
Foutstroom-
beveiliging
Fault current
protection
Foutstroom-
beveiliging
Fault current
protection
7.4kW - 22kW max
Required on-site short-circuit protection:
For 2x3.7kW/11kW
2x Circuit breaker 20A type B, or 2x 20A gG
fuses Load balancing optional
For 2x7.4kW/22kW
2x Circuit breaker 20A type B, or 2x 35A gG
fuses Load balancing optional
7.4kW - 22kW max
7.4kW - 22kW max
Feeder cable 1
Feeder cable 2
Feeder cable 1
2. PRODUCT
Installation Eve Double Pro-line with one feeder cable
supplying two sockets.
Installation Eve Double Pro-line with two feeder
cables. Each feeder cable supplying one socket.
A shared short circuit protection and overcurrent protection
may be applied to the feeder cable in the installation.
The value of the protection per feeder cable must never
exceed the output power of one outlet: A protection of 63A
on one feeder cable while the maximum output power is
32A per socket is not allowed according to the IEC-61851-1
standard.
The maximum output power is 32A per socket.
In accordance with the IEC-61851-1 standard a
maximum protection of 32A is permitted for each feeder
cable.
NOTICE!
During installation of two feeder cables there is an heightend risk of injury or hazards. Observe the installation instructions
in the User Manual or Quick Installation Guide of the Eve Double Pro-line .
2.4.1 Eve Double Pro-line with single or double feeder cables overview
NOTICE!
Please refer to appendix B for smart charging options and settings.