![Alfalaval LKHex UltraPure 10 Instruction Manual Download Page 40](http://html1.mh-extra.com/html/alfalaval/lkhex-ultrapure-10/lkhex-ultrapure-10_instruction-manual_2895565040.webp)
6 Technical data
It is important to observe the technical data during installation, operation and maintenance.
Inform personnel about the technical data.
6.3
Torque specifications
The table below specifies the tightening torques for the screws, bolts and nuts in this pump.
Always use the following torques if no other values are stated. This can be a matter of personal safety.
Size
Spanner width
Torque values
Nm
Ibf-ft
M8
13mm/0.51”
20
15
M10
17mm/0.67”
40
30
M12
19mm/0.75”
67
49
M14
22mm/0.87”
110
81
6.4
Weight (kg)
Pump Type: LKHex UltraPure
90
100
112
132
160
180
200
250
Size
1.5 kW
2.2 kW
3 kW
4 kW
5.5 kW
7.5 kW
11 kW
15 kW
18.5 kW
22 kW
30 kw
37 kw
45 kw
55 kw
75 kw
10
53
55
70
75
20
55
57
72
77
94
108
25
81
98
112
171
185
35
81
98
112
171
185
40
115
174
188
206
225
45
82
99
113
172
186
60
102
116
175
189
207
226
334
70
138
152
196
210
228
259
365
380
396
522
557
Weight can vary depending of configuration. Weight is only to be seen as a reference value during handling, transporting and packaging.