![Alfalaval LKHex UltraPure 10 Instruction Manual Download Page 17](http://html1.mh-extra.com/html/alfalaval/lkhex-ultrapure-10/lkhex-ultrapure-10_instruction-manual_2895565017.webp)
3 Installation
Read the instructions carefully and pay special attention to the warnings! Always check the pump before operation.
- See pre-use check in section 3.3 Pre-use check. The large pump sizes are very heavy. Alfa Laval therefore recommends the
use of a lifting crane when handling the pump.
Step 3
Check that the flow direction is correct.
O: Outlet
I: Inlet
3007-0007
O
I
Step 4
1. Ensure that the pipelines are routed correctly.
2. Ensure that the connections are tight.
Remember seal rings!
3007-0008
Few bends
Correct
Step 5
Avoid stress on the pump.
Pay special attention to:
-
Vibrations.
-
Thermal expansion of the tubes.
-
Excessive welding.
-
Overloading of the pipelines.
-
Piping system must be self-supported.
3007-0009
!
Note
In the event of leakage at the shaft seal, the medium will drip from the slot into the bottom of the adapter. In the instance, Alfa
Laval recommends placing a drip tray underneath the slot to collect the liquid.
17
Summary of Contents for LKHex UltraPure 10
Page 2: ......