2 Safety
All warnings in the manual are summarised in this section.
Pay special attention to the instructions below so that severe personal injury and/or damage to the pump are avoided.
Requirements for measurements on the process media
There are two principles of temperature measurements of the process media:
A. Temperature is measured on the pump outlet side (S1). No equipment with cooling effect on the process media is allowed
between pump and sensor.
B. Temperature is measured somewhere on the pump inlet side (S2). No heat generating equipment is allowed between the
temperature sensor and the pump.
3001-0062
S1
S2
Table B Measurements on process media
Temperature
sensor position
Model
Min. flow [m
3
/h]
Max. distance
to outlet [m]
LKHex UP 10-70
0,5
0,5
LKHex UP 10-60
1
10
S1 (outlet side)
LKHex UP 70
5
10
LKHex UP 10-60
1
S2 (inlet side)
LKHex UP 70
5
Anywhere on
inlet side
Requirements for measurements on the flush media (double mechanical shaft seal)
Table C Flush media limitations
Max. temperature
100°C
MIn. flow rate
30 l/h
Max. pressure
5 bar
Note: Flush media temperature must be measured no more than 2m away from the flush housing outlet.
Pumps mounted with double mechanical shaft seals can operate without the pump casing being liquid filled at all times since the
seal faces are lubricated and cooled by the flush media.