background image

-11- 

ALFA 

IN 

a.s. 

© 

   

 

 

     

www.alfain.eu

 

7.2  GETTING STARTED TIG 

 

Insert the mains plug 

41

 into a suitable 1x230 V 

mains socket. The supply fuses or circuit breaker 
should correspond to the technical data stated in this 
manual.  

 

Fit the TIG Torch to the Panel quick connector (-) 

44

 

and fasten it by turning the connector to the right.   

 

Connect the gas hose of the TIG torch onto Gas 

outlet connector 

45

 

Connect the torch control connector onto the matching connector 

43

 

Connect the work lead to Panel quick connector (+) 

42

 and fasten it by 

turning the connector to the right. 

 

Connect the gas hose to the reduction valve on the gas cylinder and on the 
Gas inlet connector 

46

 on the rear panel. 

 

Switch the machine on by the ON/OFF switch 

48

 

Select the Gas setting mode by means of pressing the button 

31

, LED 

36

 

will illuminate. Set the flow of the argon gas by means of the pressure 
reduction valve on the gas cylinder. 

 

Select 2T (two stroke) or 4T (four stroke) mode by means of switch

 1

. The 

corresponding LED will light up. 

 

Select the method desired TIG DC or AC method by means of the button 

41

. The corresponding LED will light up. 

 

In the welding torch must be installed a corresponding tungsten electrode 
(for AC green or golden). The electrode should be sharpened also 
corresponding to the AC or DC mode. 

 

Select HF or list arc ignition by means or switch 4. 

 

Set the welding current by means of Encoder 

28

. The values will be 

showed on the display 

3

.  

 

Other parameters may be set by means of buttons 

30

 and 

25

 and the 

encoder 

28

. The corresponding LEDs will light up. The set parameter will 

be automatically memorised when you move to another parameter of after 
3 s. More in the table MAIN PARTS above.  

 

Connect the work clamp to the work piece or at the welding table and you 
can start welding. 

 

The following table describes the influence setting the clearance effect. 

Clearance effect 

Value 20-30% 

Value 50% 

Shape of the current 
curve 

 

 

Penetration Deep 

Shallow 

Summary of Contents for PEGAS 200

Page 1: ...1 ALFA IN a s www alfain eu NA156 6 WELDING INVERTER PEGAS 200 AC DC PULSE OPERATING MANUAL...

Page 2: ...TO ORDER 7 6 OPERATOR CONTROLS 8 6 1 MAIN PARTS 8 7 GETTING STARTED 10 7 1 GETTING STARTED MMA COATED ELECTRODE 10 7 2 GETTING STARTED TIG 11 7 3 REMOTE CONTROL 12 8 TWO STROKE AND FOUR STROKE IN TIG...

Page 3: ...ntire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product Read and understand this entire Manual and your employer s sa...

Page 4: ...ric shock flashes and sparks from welding The operator must protect his eyes with safety visor or mask designed for welding fitted with standard safety filters He should also be aware that during elec...

Page 5: ...of electric shock DC current 113V peak value AC current 68V peak value and 48V effective 2 Places without increased risk of electric shock DC current 113V peak value AC current 113V peak value and 80V...

Page 6: ...68 Welding current DC 100 I2 U2 ta 40 oC A V 70 22 8 80 23 2 Welding current DC 60 I2 U2 ta 40 oC A V 90 23 6 110 24 4 Welding current DC x I2 U2 ta 40 oC A V 20 170 26 8 25 170 26 8 Welding current D...

Page 7: ...changes updates improvements or replacement of such items 5 EQUIPMENT 5 1 CONTENT OF DELIVERY Item No Description Quantity 5 0172 PEGAS 200 AC DC PULSE 1 5 0189 Set of Connectors for PEGAS AC DC 1 5...

Page 8: ...4T 5 100 of the main welding current DC 10 100 AC Default 5 5 LED Up slope 0 10 s default 0 s 6 LED Main Welding Current 5 200 TIG DC 10 200 TIG AC 5 170 MMA DC 10 170 MMA AC 7 LED ratio of the pulse...

Page 9: ...sing button 1 23 LED Arc Length 0 10 24 LED HOT START 0 10 25 Button for moving to the right on the parameters curve 26 LED Balance just TIG AC Used for elimination of the aluminium oxides Range 15 50...

Page 10: ...the instruction on the electrodes packing Switch the machine on by the ON OFF switch 48 Set the welding current by means of Encoder 28 The values will be showed on the display 3 It is possible to cha...

Page 11: ...duction valve on the gas cylinder Select 2T two stroke or 4T four stroke mode by means of switch 1 The corresponding LED will light up Select the method desired TIG DC or AC method by means of the but...

Page 12: ...l welding current P3 Connector connect to matching connector 13 on the front panel When you connect the P3 connector to matching connector on the front panel 43 the function setting the current from t...

Page 13: ...main welding current To enter the second welding current press the torch button for a short time and release it To get back to the main welding current press the torch button for a short time and rele...

Page 14: ...tine maintenance required for the PEGAS range of machines is a thorough cleaning and inspection with the frequency depending on the usage and the operating environment WARNING Disconnect the PEGAS fro...

Page 15: ...ct your ALFA IN product supplier for the warranty repair procedure ALFA IN warranty will not apply to Equipment that has been modified by any other party other than ALFA IN s own service personnel or...

Page 16: ...16 ALFA IN a s www alfain eu compatible recycling facility...